8,000/10,000/12,000 BTU Portable Air Conditioner Operating Instructions Model No.: PS08-01 PS10-01 Ref: KY80 KY100 Model No.
Thank you for choosing a Soleus Air Portable Air Conditioner. This owner’s manual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new Soleus Air Portable Air Conditioner. For your own records, please attach a copy of your sales receipt to this manual.
PACKAGE CONTENTS Portable Air Conditioner (1) Exhaust Hose (1) Exhaust Hose Connector (1) Window Kit Adapter (1) Window Kit Adapter Extension (1) Rubber Plug (1) Screws (2) Remote Control (1) AAA Batteries (2) Caster Lock (2) Window Kit - Sliding Panels (3) Drainage Hose (1) SPECIFICATIONS The cooling capacity is measured at an ambient temperature of DB 95˚F, WB 83 ˚F. Noise level is measured at a distance of 3.28 ft away from the front of the unit, when the unit is in cooling mode.
LCDI POWER CORD AND PLUG This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side.
ALTERNATIVE LCDI POWER CORD AND PLUG WITH LED LIGHT This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side.
PRODUCT DIAGRAM 1. Air Outlet Grill 2. Control Panel 3. Casters 4. Air Intake Grill 5. Remote Control Sensor 6. Air Filter 7. Carry Handle 8. Air Exhaust Hose Discharge Opening 9. Condensation Drain Hole 10. Power Cord 11. Exhaust Hose 12. Window Kit Adapter 13. Exhaust Hose Connector 14. Remote Control 15. Caster Locks 16. Screws 17.Window Kit 18. Window Kit Adapter Extension 19. Drainage Hose 20. Rubber Plug 21.
PARTS & ASSEMBLY PARTS ASSEMBLY & INSTALLATION INSTALLATION When the unit is operating as an air conditioner or dehumidifier, the unit draws in indoor air and exhausts hot air out of the room to complete the air exchange. When the unit is operating in fan mode no outdoor air exchange takes place. The window kit and exhaust hose do not need to be installed when the unit is used as a fan. NOTE: The supplied window kit can be installed in sliding windows and sliding glass doors up to 4.6 ft.
WINDOW KIT INSTALLATION FOR SINGLE HOSE AIR CONDITIONER The venting kit must be installed in order for the unit to work correctly in the air conditioner mode, dehumidifying mode, and auto mode. The venting kit should not be used while the unit is fanning. The window kit has been designed to fit into most vertical and horizontal window openings. 1. Screw the Exhaust Hose Connector onto one end of the Exhaust Hose. 2. Connect the Exhaust Hose over the discharge opening on the back of the unit. 3.
WINDOW KIT ASSEMBLY GUIDE SCREW PANEL SCREW 1.Parts: A) Panel B) Panel with one exhaust hose opening C) Panel without exhaust hose opening D) Pins to lock window kit in place 2. Assembly: Slide Panel B and C into Panel A and size to window width. Windows sizes vary. When sizing the window width, be sure that the window kit assembly is free from gaps and/or air pockets when taking measurements. 3.
CONTROL PANEL, DISPLAY, & OPERATING INSTRUCTIONS CONTROL PANEL Fan Mode Indicator Decrease Temperature Button Sleep Mode Indicator Auto Mode Indicator Fan Speed Indicator Increase Temperature Button POWER ON/OFF Button Airflow Auto-Swing Button Mode Selection Button Dehumidifier Mode Indicator Air Conditioner Mode Indicator Timer Indicator Fan Mode Button OPERATING INSTRUCTIONS CONTROL PANEL BUTTONS 1) Power On and Off - Press the POWER button once to manually turn the unit on.
OPERATING THE UNIT USING THE REMOTE CONTROL REMOTE CONTROL LCD DISPLAY POWER BUTTON MODE BUTTON TIMER/TEMP INCREASE TIMER BUTTON TIMER/TEMP DECREASE SLEEP BUTTON FAN SPEED °C /°F BUTTON SWING BUTTON THIS BUTTON DOES NOT HAVE A FUNCTION * Remote Colors may differ from the image above.
REMOTE CONTROL OPERATING INSTRUCTIONS 1) Power On and Off - If the unit is already on, press the POWER button on the remote while pointing the remote away from the unit. This will turn the remote on. If the unit is off, now press the POWER button once to manually turn the unit on. Press the POWER button once more to turn the unit off. When in Air Conditioner mode, the selected temperature will appear on the remote control LCD display.
7) SWING - To turn on oscillation, press the SWING button on the remote control when the unit is in air conditioner mode, fan mode, and dehumidifier mode. The remote control will show an arrow ► by to the “SWING” icon on the remote control LCD display. Once you press SWING, the louvers on the unit will oscillate left and right. OPERATING THE UNIT Air Conditioner Mode 1) Install the exhaust hose and window kit properly (see pages 7 & 8). 2) Plug the Power Cord into an electrical outlet.
Auto Mode 1) Install the exhaust hose and window kit properly (see pages 7 & 8 ). 2) Plug the Power Cord into an electrical outlet. 3) Turn on the unit by pressing the POWER button. 4) Press the MODE button until the Auto mode indicator appears on the control panel display. NOTE: During Auto mode, the unit operates in Fan mode when the room temperature is below 73˚F, and Air Conditioner mode when the room temperature is above 73˚F.
MAINTENANCE Note: Make sure power is off and the power cord is not plugged into an electrical outlet prior to performing any maintenance on the unit. Clean or replace filter - If the air filter is blocked with a dust, the airflow volume may reduce. It is recommended to clean the filter once every two weeks or as needed. 1) Remove the filter from the filter compartment on the left of the unit. 2) Wash the air filter by immersing it gently into warm water with a neutral detergent.
TROUBLESHOOTING PROBLEM CAUSE SOLUTION Air conditioner does not power on • Unit is not plugged in. • No electric current to outlet. • Internal safety device has tripped. • Plug unit in. • Check electric breaker box for a trip. • Wait 30 minutes for safety device to reset. Air conditioner works for a limited amount of time • There are bends in the exhaust hose. • Something is blocking the air from being discharged.
SELF-DIAGNOSIS SYSTEM MALFUNCTION CODES SELF-DIAGNOSIS The appliance has a self diagnosis system to identify a number of malfunctions. Error messages are displayed on the appliance display.
WARRANTY One Year Limited Warranty Soleus Home Comfort warrants the accompanying Soleus Air Portable Air Conditioner to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE (1) year from the date of original retail purchase in the United States.