Portable Air Conditioner, Heat Pump Heater, Dehumidifier, Fan, & HEPA Air Purifier PA1-10R-32 Operating Instructions 3046364 Model No.
Thank you for choosing a Soleus Air Portable Air Conditioner. This owner’s manual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new Soleus Air Portable Air Conditioner. For your own records, please attach a copy of your sales receipt to this manual.
PACKAGE CONTENTS Portable Air Conditioner Exhaust Hoses (1) Hose Adapters (1) Window Kit Adapter (1) HEPA Filter (1) Remote Control AAA Batteries (2) Window Kit - 3 Sliding Panels (1 single hose panel, 2 extension panels) Owner’s Manual SPECIFICATIONS • The cooling capacity is measured at an ambient temperature of DB 86 °F, WB 78 °F. • Noise level is measured at a distance of 3.28 ft away from the front of the unit, when the unit is in cooling mode.
PRODUCT DIAGRAM (Actual product design may differ slightly from images below) FRONT A A. Control panel B. Air outlet B C. Casters D. Power Cord & Plug E. Drain Plug F F. HEPA Air Filter Storage D E C BACK D A. Hot air outlet grill B. Lower air inlet grill C C. HEPA Air Filter Holder D.
INSTALLATION SELECTING THE LOCATION Place the unit in a flat location where the air outlets are not obstructed. Place the unit at least 20” (50cm) away from a wall or other obstacle. MOUNTING THE EXHAUST HOSE Slide the square end of the exhaust duct over the hot air outlet on the back of the unit. The exhaust hose should be kept as short and straight as possible. Prevent any sharp bends in the exhaust hose, as this will trap hot exhaust air.
LCDI POWER CORD AND PLUG This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side.
WINDOW KIT INSTALLATION WINDOW KIT INSTALLATION The window kit is designed to fit into most standard vertical and horizontal windows, as well as some sliding glass doors. However, it may be necessary to modify some aspects of the installation process for certain window types. • Open the window or sliding door and adjust the length of the window kit to fit the opening. If the window kit is not long enough, connect the extra window kit panel to fit the opening.
WINDOW KIT INSTALLATION (cont’d) NOTE: The Portable Air Conditioner above may differ from the unit described in this manual. The above directions and images show general directions for all Soleus Air single hose portable air conditioners.
CONTROL PANEL, DISPLAY, & OPERATING INSTRUCTIONS CONTROL PANEL & MULTI-COLOR DISPLAY ▲ ▼ MULTI-COLOR DISPLAY AUTO A/C DEHUM.
OPERATING INSTRUCTIONS CONTROL PANEL BUTTONS (Refer to the images on page 9) 1) Power On and Off - Press the POWER button once to manually turn the unit on. Press the POWER button once more to turn the unit off. 2) Mode Selection - Press the MODE Button repeatedly to cycle between the different modes: Auto mode, Air Conditioner, Dehumidifier, Fan only, and Heater mode. Air Purifier Mode is a separate function, see page 13 for Air Purifier Operation.
6) Select the desired fan speed by pressing the SPEED button. NOTE: During hot days, the unit will cool the room most efficiently by setting the temperature at the lowest setting and the fan speed on high. Reducing the length of the exhaust duct, insulating the exhaust hose and window kit, and keeping direct sunlight to a minimum will also improve the cooling efficiency. NOTE: When the unit is running on cooling mode, the exhaust hoses are required and must be vented outside using the supplied window kit.
Auto Mode 1) Install the exhaust hoses and window kit properly (see pages 7 & 8). 2) Plug the Power Cord into an electrical outlet. 3) Turn on the unit by pressing the POWER button on the control panel. 4) Press the MODE button until the “ by pressing the FAN SPEED button. ” icon appears on the control panel display.
AIR PURIFIER FUNCTION The PA1-10R-32 is equipped with a HEPA air purification mode. This mode is only available when the HEPA air filter has been inserted into the Air Filter Holder. Please note, when the air filter is inserted into the air cleaner, the PA1-10R-32 will ONLY operate in air purifier mode. All other modes are not available when this mode is selected. To Operate Air Purifier Mode: 1. Disconnect the exhaust hose from the back of the air conditioner. 2.
OPERATING THE UNIT USING THE REMOTE CONTROL REMOTE CONTROL LCD DISPLAY MODE BUTTON FAN SPEED SWING (LOUVER OSCILLATION) SLEEP BUTTON HOUR SELECTER POWER BUTTON TEMP SETTING TIMER ON TIMER OFF MINUTE SELECTER 14
REMOTE CONTROL OPERATING INSTRUCTIONS 1) Power On and Off - Press the POWER (I/O) button on to turn the unit on or off When you press the POWER button (when turning the unit on) the upper right square on the remote control LCD Display will light up. When in Air Conditioner, Heating, and Auto mode, the selected temperature will appear on the remote control display. When the unit is in Fan mode and Dehumidifier mode you will see the “- -” icon instead of the set temperature.
Emergency Condensate Holding Tank When the room temperature is low and the indoor humidity is high, the air conditioner may not be able to evaporate some of the moisture fast enough. When this happens, the water will accumulate in an emergency condensate tank inside the unit. Once the emergency condensate tank is full, the unit will automatically shut off and the “ ” will appear on the control panel display.
MAINTENANCE Note: Make sure power is off and the power cord is not plugged into an electrical outlet prior to performing any maintenance on the unit. Clean or replace particulate air filter (Black Mesh Filter) - If the air filter is blocked with a dust, the airflow volume may reduce. It is recommended to clean the filter once every two weeks or as needed. 1) Remove the filter from the filter compartment on the back of the unit.
WARRANTY One Year Limited Warranty Soleus International Inc. warrants the accompanying Soleus Air Portable Air Conditioner to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE (1) year from the date of original retail purchase in the United States. If the unit exhibits a defect in normal use, Soleus International Inc.