Model WS3-06E-201 WS3-08E-201 6,000 BTU 8,000 BTU Electronic Hybrid Air Conditioner Operating Instructions 4010450 Air conditioner must be upright for 24 hours prior to operating. This ensures that the compressor will function as intended.
PURCHASE INFORMATION Thank you for choosing a Soleus Air Hybrid Air Conditioner. This Owner’s Manual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new Soleus Air Window Air Conditioner. For your own records, please attach a copy of your sales receipt to this manual.
POWER CORD AND PLUG This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side.
PACKAGE CONTENTS • • • • • • • • Hybrid Air Conditioner (1) Remote Control (1) AAA Battery (2) Window Slider A Short (2) Window Slider B Short (2) Window Slider A Long (1) Window Slider B Long (1) Mounting Block (2) • • • • • • Window Slider Support Bracket (2) Adjustable Support Knob (2) Top Foam Sealer (1) Bubble Level (1) Optional Window Security Bracket - Security Bracket (1) , Type B Screw (1) Owner’s Manual (1) Remote Control Air Conditioner (2) - Window Slider A Short 2 AAA Batteries (2) - Wi
SPECIFICATIONS • Noise level is measured at a distance of 3.28 ft away from the front of the unit in cooling mode. • Power consumption is measured when the fan runs at the highest speed setting. • These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit. Model Power Supply (Ph/V/Hz) WS3-06E-201 WS3-08E-201 1/115/60 1/115/60 6,000 8,000 Cooling Power Input (Watts) 495 667 Rated Current Cooling (Amperage) 4.5 6.5 CEER 12.1 12.
ELECTRICAL SAFETY WARNING: grounding prong!! Power supply cord with 3-prong grounding plug and current detection device DISCLAIMER ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER’S MANUAL ARE THE PRESENATION OF THE MANUFACTURER. SOLEUS N.A. HAS NOT CONDUCTED AN INDEPENDENT TEST TO VERIFY THE INFORMATION AND SPECIFICATIONS PRESENTED HEREWITHIN.
INSTALLATION Window Preparation Please read all instructions prior to installing your air conditioner. Two people are recommended to install this product. If a new electrical outlet is required, have the outlet installed by a qualified electrician before installing the unit. Before installing the unit, check the dimensions of your window to make sure the air conditioner will fit. This unit is made to fit inside a standard double-hung window. Make sure the window is in good shape.
INSTALLATION 1. Attach Mounting Blocks on Window Frame (See Fig.1) 1) Remove adhesive from mounting block and place mounting block on window frame. 2) Press down firmly on the mounting block to secure in place. 3) Then, remove adhesive from the other mounting block and place mounting block on window frame. 4) Press down firmly on the mounting block to secure in place. 5) The mounting block are now ready to support the Hybrid Air Conditioner. Fig.1 2.
INSTALLATION 4. Install Window Sliders 1) Connect the window sliders together. Short and long window sliders are included to accommodate various window opening sizes. 2) Slide window sliders into both support brackets on either side of the Hybrid Air Conditioner. (See Fig.6) *Window sliders can be shortened by cutting with a handsaw so that it fits inside the opening. Fig.5 Fig.6 5.
CONTROL PANEL Electronic Control Panel & Remote Control Note: This control panel display always shows the room temperature in Fan Mode except when setting the temperature and timer. Normal Operating Sounds You may hear a pinging noise caused by water hitting the condenser on rainy days, or when the humidity is high. This design feature helps remove moisture and improve efficiency. • You may hear the thermostat click when the compressor cycles on and off.
REMOTE CONTROL POWER BUTTON UP ARROW (TEMP/TIMER) MODE BUTTON DOWN ARROW (TEMP/TIMER) FAN SPEED CHILD LOCK BUTTON MYTEMP MODE BUTTON SLEEP BUTTON TIMER BUTTON ENERGY SAVER BUTTON AUTO MODE BUTTON Battery Size: AAA - NOTE: Do not mix old and new batteries or different types of AAA batteries. .
OPERATION INSTRUCTIONS 1. ON/OFF - Press the POWER button to turn the A/C on or off. When the unit is turned off, the Timer function will be cancelled. The set temperature will be saved. 2. MODE SELECTION - Press the MODE button repeatedly to cycle between the different modes: Cool, Dry (Dehumidifier) and Fan. 3. TEMPERATURE SETTING - Press the ▼ button to decrease the temperature when the unit is on. Stop pressing the button when the desired temperature is displayed. Temperature range is 62⁰F-86⁰F.
USE THE AIR CONDITIONER Freezing Conditions: This is a cooling only air conditioner. It is not designed for freezing outdoor conditions. It must not be used in freezing outdoor conditions. Remote Control: To ensure proper operation when using the remote control, aim the remote directly at the signal receiver on the air conditioner. • The remote control has a signal range up to 20 feet. • Make sure nothing is blocking the remote control signal from being received by the air conditioner.
USE AND CARE CARE AND CLEANING Clean your air conditioner to keep it looking new and to minimize dust build up. Air Filter Cleaning The air filter should be checked at least once every month to see if it needs cleaning. Trapped particles and dust can build up in the filter and may decrease airflow as well as cause the cooling coils to accumulate frost. To clean the air filter: 1. Remove the filter by pulling on the indents of the front panel on the top, right and left side of the unit. 2.
TROUBLESHOOTING PROBLEM The Air Conditioner will not start The Air Conditioner does not cool as it should The Air Conditioner is freezing up POSSIBLE CAUSES SOLUTIONS The air conditioner is unplugged • Make sure the air conditioner plug is pushed completely into the outlet. The fuse is blown/circuit breaker is tripped • Check the main fuse/circuit breaker box and replace the fuse or reset the breaker. Power failure • The unit will automatically restart when power is restored.
TROUBLESHOOTING PROBLEM POSSIBLE CAUSES SOLUTIONS Water is dripping outside Hot and humid weather • This is normal Water is dripping inside the room The air conditioner is not correctly tilted towards the outside • For proper water drainage, make sure the air conditioner is slightly tilted downward from the front of the unit to the rear. The drain plug is unplugged. • Firmly press on the drain plug at the front, bottom-left side of the unit.
LIMITED WARRANTY One Year Limited Warranty Soleus N.A. warrants the accompanying Soleus Air Air Conditioner to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of One (1) year from the date of original retail purchase in the United States. If the unit exhibits a defect in normal use, Soleus N.A. will, at its option, either repair or replace it, free of charge within a reasonable time after the unit is returned during the warranty period.