8,000 BTU Portable Air Conditioner Operating Instructions 3092402 V021014 Model No.
Thank you for choosing a Soleus Air Portable Air Conditioner. This owner’s manual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new Soleus Air Portable Air Conditioner. For your own records, please attach a copy of your sales receipt to this manual.
PACKAGE CONTENTS Portable Air Conditioner (1) Exhaust Hose (1) Hose Adapter (1) Window Kit Adapter (1) Window Kit Adapter Extension (1) Remote Control (1) AAA Batteries (2) Window Kit - 3 Sliding Panels (1 single hose panel, 2 extension panels) Owner’s Manual (1) SPECIFICATIONS The cooling capacity is measured at an ambient temperature of DB 86 °F, WB 78 °F. Noise level is measured at a distance of 3.28 ft away from the front of the unit, when the unit is in cooling mode.
LCDI POWER CORD AND PLUG This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side.
PRODUCT DIAGRAM Remote Control Control Panel (on top) Louvers Remote Control Signal Receptor Casters Filter Compartment Condenser Air Outlet Evaporator Air Intake Condenser Air Intake Drain Hole Drain Port Rubber Plug 5
PARTS & ASSEMBLY PARTS EXHAUST HOSE WINDOW KIT ASSEMBLY & INSTALLATION INSTALLATION When the unit is operating as an air conditioner or dehumidifier, the unit draws in fresh outdoor air and exhausts hot air out of the room to complete the air exchange. When the unit is operating in fan mode no outdoor air exchange takes place. The window kit and exhaust hose do not need to be installed when the unit is used as a fan.
WINDOW KIT INSTALLATION Installation of the Venting Kit FOR SINGLE HOSE PORTABLE AIR CONDITIONERS The venting kit must be installed in order for the unit to work correctly in the air conditioning mode. The venting kit should not be used while the unit is heating or fanning. The window kit has been designed to fit into most vertical and horizontal window openings. The window kit can also be used in a sliding door. 1. 2. 3. 4. 5. 6.
WINDOW KIT ASSEMBLY 1.Parts: A) 2 Track Screws B) 2 Wing Nuts C1 & C2) 2 Hose Panels, one Exhaust Hose Openings D) 1 Sliding Track Panel 5. Next, take the other Hose Panel (C2) and connect it to Hose Panel (C1) by placing the Sliding Track Panel (D) over the Track Screw (A) on Hose Panel (C2). 2. Assembly: First, take the Track Screws (A) and screw one into each of the small holes found on the Hose Panels (C1 & C2). 6. The Hose Panels (C1 &C2) should now be connected using the Sliding Track Panel (D).
CONTROL PANEL, DISPLAY, & OPERATING INSTRUCTIONS CONTROL PANEL TEMPERATURE AND TIMER INDICATOR AIR CONDITIONER MODE DEHUMIDIFIER MODE BUCKET FULL FAN MODE MODE BUTTON TIMER/TEMP DECREASE POWER BUTTON TIMER/TEMP INCREASE OPERATING INSTRUCTIONS CONTROL PANEL BUTTONS 1) Power On and Off - Press the POWER button once to manually turn the unit on. Press the POWER button once more to turn the unit off.
OPERATING THE UNIT USING THE REMOTE CONTROL REMOTE CONTROL LCD DISPLAY MODE BUTTON POWER BUTTON FAN SPEED TEMP SETTING TIMER ON SLEEP BUTTON TIMER OFF MINUTE SELECTER HOUR SELECTER * Remote Colors may differ from the image above.
REMOTE CONTROL OPERATING INSTRUCTIONS 1) Power On and Off - If the unit is already on, press the POWER (I/O) button on the remote while pointing the remote away from the unit. This will turn the remote on. If the unit is off, now press the POWER (I/O) button once to manually turn the unit on. Press the Power button once more to turn the unit off. When you press the POWER button the upper right square on the remote control LCD Display will light up.
NOTE: you can set either T-ON or T-OFF, also can set both T-ON and T-OFF . If you set both T-ON and T-OFF simultaneously, the timer will always cycle effectively unless removed either T-ON or T-OFF. Caution: a) Do Not Mix Old And New Batteries. Do Not Mix Alkaline, Standard (Carbon - Zinc), Or Rechargeable (Nickel - Cadmium) Batteries. b) Do not connect improperly, charge or dispose of in fire, battery may explode or leak. c) Remove batteries when the remote control is not in use for an extended time.
Fan Mode 1) 2) 3) 4) Plug the Power Cord into an electrical outlet. Turn on the unit by pressing the POWER button on the control panel. Press the MODE button until the fan mode icon light up on the control panel display. Select the fan speed by pressing the FAN button by using the Remote control. NOTE: It is not necessary for the exhaust hose and window kit to be installed to operate the unit in fan mode. Auto Mode 1) Install the exhaust hose and window kit properly (see pages 7 & 8 ).
MAINTENANCE Note: Make sure power is off and the power cord is not plugged into an electrical outlet prior to performing any maintenance on the unit. Clean or replace filter - If the air filter is blocked with a dust, the airflow volume may reduce. It is recommended to clean the filter once every two weeks or as needed. 1) Remove the filter from the filter compartment on the left and back of the unit. 2) Wash the air filter by immersing it gently into warm water with a neutral detergent.
WARRANTY One Year Limited Warranty Soleus Home Comfort warrants the accompanying Soleus Air Portable Air Conditioner to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE (1) year from the date of original retail purchase in the United States.