Model HCC-W08ES-A1 HCC-W10ES-A1 Electronic Window Air Conditioner Operating Instructions V.
Thank you for choosing a Soleus Air Air Conditioner. This owner’s manual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new air conditioner. For your own records, please attach a copy of your sales receipt to this manual.
LCDI POWER CORD AND PLUG This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and plug as required by US National Electric Code 440.65. This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side.
PACKING LIST Top Mounting Rail Air Conditioner Foam Seal Top Mounting Rail Insert Strip Accordion Panel Short Screw Long Screw Sash Lock Curtain Lock Packing List: • • • • • • • Window Air Conditioner (1) Remote Control (1) AAA Batteries (2) Top Mounting Rail (1) Insert Strip (1) Short Screw (8) Accordion Panels (2) • • • Sash Lock (2) Foam Seal (1) Long Screw for Window Locking Bracket & Accordion Panels (12) Curtain Lock (2) Owner’s Manual (1) • • 3
SPECIFICATIONS • Noise level is measured at a distance of 3.28 ft away from the front of the unit in cooling mode. • Power consumption is measured when the fan runs at the highest speed setting. • These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit. Model HCC-W08ES-A1 HCC-W10ES-A1 1/115/60 1/115/60 Rated Cooling Capacity (BTU/h) 8,000 10,000 Cooling Power Input (Watts) 708 885 Rated Current Cooling (Amperage) 6.8 7.9 11.
INSTALLATION & ASSEMBLY INSTRUCTIONS Some assembly is required for your new air conditioner. Please read and follow these instructions carefully. 1. This air conditioner is designed to be installed in a standard double-hung window with a window width between 23” and 36” (584 mm - 914 mm). 2. The air conditioner can be installed without the accordion panels to fit in a narrow window opening. See the window dimensions. 3. The Lower Sash (the lower part of the window that moves up and down) must allow for 14.
TOP RAIL INSTALLATION NOTE: Top Rail and the side Panels are offset to provide the proper pitch to the rear of (5/16”). This is necessary for proper condensation utilization and drainage. If you are not using the side panels, the rear pitch must still be maintained. n t i n gr a i l mo u 1. Attach the top rail onto the top of the outer case using four Short Screws.
ASSEMBLY & INSTALLATION (CONT.) Accordion Panel Installation Placing the Unit Inside a Normal Window Now that you have installed the top rail, you can now install 1. Place the air conditioner on the sill with the bottom mounting rail against its back edge. Center the air conthe accordion panels on each side. ditioner and close the window securely behind the top mounting rail. The air conditioner should be slightly 1. Place the air conditioner on a hard flat surface. tilted to the outside area.
ASSEMBLY & INSTALLATION (CONT.) IF AC is Blocked by a Storm Window A storm window frame will not allow the air conditioner to tilt properly which in turn will keep it from draining properly. To adjust for this, attach a board or piece of wood to the sill. The board or wood piece should have a depth of at least 1 1/2”. Make sure the board or piece of wood is approximately 1/2” higher than the storm window frame. This will allow the air conditioner to tilt enough for proper drainage. (See FIG. 4). FIG.
USING YOUR AIR CONDITIONER Electronic Control Panel & Remote Control NOTE: This display always shows the room temperature in Fan Mode except when setting the Set temperature or the Timer 3. Temperature Set: Use these buttons on the control panel and remote to increase or decrease the Set Temperature (the desired room temperature) in cooling,energy saver and dry mode. To switch between Celsius/Fahrenheit display, press the ▲/▼ buttons at the same time. 4.
OPERATING YOUR AIR CONDITIONER REMOTE CONTROL COOL - Press the COOL button to turn cooling mode on or off. 8. DRY - Press the DRY button to turn dehumidifying mode on or off. Fan speed can only be set to low in this mode. 9. FILTER RESET - Press the FILTER RESET button to turn off the "CHECK FILTER" LED light when on. 10. ENERGY SAVER - Press the ENERGY SAVER button to turn on energy saver mode. When the unit is in energy saver mode, the Energy Saver light will turn on.
USING YOUR AIR CONDITIONER • Freezing Conditions: This is a cooling only air • conditioner. It is not designed for freezing outdoor conditions. It must not be used in freezing outdoor conditions. • Remote Control: To ensure proper operation when using the remote control, aim the remote directly at the signal receiver on the air conditioner.
CARE AND CLEANING Clean your air conditioner to keep it looking new and to minimize dust build up. Cabinet Cleaning To clean the air conditioner cabinet: Unplug the air conditioner to prevent shock or a fire hazard. The cabinet and front panel of the air conditioner may be dusted with an oilfree cloth or washed with a cloth dampened in a solution of warm water and mild liquid soap. Rinse thoroughly with a damp cloth and wipe dry.
TROUBLESHOOTING PROBLEM POSSIBLE CAUSES SOLUTIONS The Air Conditioner will not start The air conditioner is unplugged • Make sure the air conditioner is plug is pushed completely into the outlet The fuse is blown/circuit breaker is tripped. • Check the house fuse/circuit breaker box and replace the fuse or reset the breaker. Power Failure • The unit will automatically re-start when power is restored. There is a protective time delay (approx.
TROUBLESHOOTING (CONT.) PROBLEM POSSIBLE CAUSES SOLUTIONS Water is dripping outside Hot and Humid weather. • This is normal Water is dripping inside the room The air conditioner is not correctly tilted outside. • For proper water drainage, make sure the air conditioner is slightly tilted downward from the front of the unit to the rear. Water collects in the base pan Moisture removed from the air is draining into the base pan.
Warranty Soleus Home Comfort warrants the accompanying Soleus Air Air Conditioner to be free of defects in material and workmanship for the applications specified in its operation instruction for the period of parts specified below. 5 YEARS FOR COMPRESSOR 1 YEAR FOR OTHER COMPONENTS This warranty shall not apply to broken or marred cabinets, accessories, knobs, filters or routine maintenance.