If ODU is not connected in the right order, related devices may fail to communicate with
each other or the unit may read wrong information. Given this, you need to connect the unit with
accurate RF Port and Signal Port in a corresponding number.
For unused RF Ports for ODU expansion, make sure to terminate them using SMA Term.
When you put ODU on the top of BIU, it is recommended to install the unit at least 1U
apart from BIU. Heat from BIU climbes up to reach ODU.
5.1.6 Consumption Power of BIU
The table below shows power consumption of BIU:
Part Unit Consumption Power Remark
Shelf
MCDU
MCPU
Common Part
MPSU
7.5 W
MDBU 800PS 12W
MDBU 800PS+900I+Paging 20W
MDBU 850C 12W
MDBU 850C+700PS 19W
MDBU 1900P 20W
MDBU
MDBU AWS-1 12W
BIU supplies power for ODU. Therefore, when you want to calculate total power consumption of
BIU, you need to add power consumption of ODU to the total value.
Power consumption of ODU is given in the later paragraph describing ODU.