3.1 ROU Installation
3.1.1 ROU Enclosure installation
The ROU enclosure has two options. One meets NEMA4 standard and the other is not waterproof or
dirtproof. The ROU can be mounted on a Wall easily. Rack mounting is also possibleusing special
frame. There are 3 different types and they will be explained later in this chapter. The ROU consists
of anMRU and anARU. Their dimensions are thesame.
The following shows the dimension of the mounting holes for the Wall Mount Bracket.
Figure 3.1 Wall mount dimensions for the ROU
ROU Wall Mount Installation
There are two way to install the ROU on the wall. One is to install ROUs on the wall side by side, the
other is stack the ARU above the MRU.
Type1 : Side by Side installation
Install M8 mounting Screws roughly half way in, insert the wall mount bracket over the 2 screws and
secure it with the last 2 screws.
For convenience, the Wall Mount Bracket has mounting holes to let you easily mount an enclosure.
Screw the M6 Wrench Bolts by half at each side of the Heatsink enclosure.