S DR-NH SMD H124 4 Ins stallatiion an nd Ope eration n Manual Document Re eference: Version: V6.0 Docu ument Statuss: Release 1 Issue e Date: May.
REVISION HISTORY No. of Pages Version Issue Date Initials Details of Revision Changes V 1.0 Jan. 02, 2009 V 2.0 Oct. 23. 2009 Add RDU(VHF+UHF) V 3.0 Feb. 04. 2010 Add ADD ON V/UHF ROU V 4.0 Nov. 24. 2010 Add RDU E-VHF+UHF V 5.0 Feb. 21, 2011 LTE FULL BAND V 6.0 May. 22, 2012 Add 700LTEF+850C Original Technical Support SOLiD serial numbers must be available to authorize technical support and/or to establish a return authorization for defective units.
Contents Section1 Safety & Certification Notice................................................................... 9 Section2 System Overview ................................................................................... 12 2.1 General overview ......................................................................................... 13 2.2 System overview .......................................................................................... 14 Section3 System Specifications ...................
.4.1 Specifications of ROU ........................................................................... 47 4.4.2 Block Diagram of ROU .......................................................................... 48 4.4.3 ROU parts ............................................................................................... 48 4.4.4 Function by unit ..................................................................................... 50 4.4.5 Bottom of ROU ............................................
.4.3 OEU Optic Cabling ............................................................................... 104 5.4.4 Insert DOU to OEU ............................................................................... 105 5.4.5 Consumption Power of OEU ............................................................... 105 5.5 ADD ON V/UHF ROU Installation .............................................................. 106 5.5.1 AOR Enclosure installation.........................................................
Contents of Figure Figure 2.1 – Basic system topology ............................................................... 14 Figure 2.2 – Expansion system topology ....................................................... 15 Figure 4.1 – BIU outer view ............................................................................ 25 Figure 4.2 – BIU mounting diagram ............................................................... 26 Figure 4.3 – MDBU Outer Look .......................................................
Figure 4.22 – ERFM Outer Look .................................................................... 45 Figure 4.23 – OEU front panel Outer Look..................................................... 46 Figure 4.24 – Rear panel Outer Look ............................................................. 46 Figure 4.25 – ROU Outer Look ...................................................................... 47 Figure 4.26 – ROU Inner Look .......................................................................
Figure 5.10 – Installation flow diagram when AOR installs in the rack ......... 109 Figure 5.10 – AOR which is installed above of ROU .................................... 113 Figure 5.11 – AOR which is installed under of ROU .....................................
Section1 Safety & Certification Notice Confidential & Proprietary 9/139
“Only qualified personnel are allowed to handle this unit. Read and obey all the warning labels attached in this user manual” Any personnel involved in installation, operation or service of the SOLiD Technology repeaters must understand and obey the following: - Obey all general and regional installation and safety regulations relating to work on high voltage installations, as well as regulations covering correct use of tools and personal protective equipment.
-For PLUGGABLE EQUIPMENT, the socket-outlet shall be installed near the equipment and shall be easily accessible.
Section2 System Overview 2.1 General overview 2.
2.1 General overview SMDR-NH124 is a coverage system for in-building services delivering voice and data in high quality and for seamlessly. As a distributed antenna system, it provides analog and digital phone systems that are served in multiple bands through one antenna. The system covers general public institutions and private facilities. z Shopping malls z Hotels z Campus areas z Airports z Clinics z Subways z Multi-use stadiums, convention centers, etc.
z 2.2 Sign nals with a plurality of service provide er transmit simultaneouslly Sup pport multi-op perator in a band b Low OPEX / CAPEX X Com mpact design n Upg gradable dessign Eassy installation n and mainte enance Web b Based SNM MP or GSM Modem or UDP U support (Optional) System overview o SMDR-NH124 is composed of o devices givven below. Basiccally, the sysstem consistts of BIU (BT TS Interfcace Unit), ODU U (Optic disttribution Unit) and ROU (Remote Op ptic Unit).
Fig gure 2.2 – Ex xpansion sy ystem topolo ogy Table 3.1 – System topo ology Charts Sys stem elemen nts Opttical Loss [d dBo] Max.
Section3 System Specifications 3.1 System specifications 3.1.1 Physical Specifications 3.1.2 Optic wavelength and Laser power 3.1.3 Environmental specifications 3.1.4 Operating Frequencies range 3.1.
System specifications 3.1 3.1.
3.1.2 Optic wavelength and Laser power Parameter ODU OEU ROU West optic TX: 1310nm TX: 1550nm, RX: 1550nm East optic RX: 1310nm TX: 1550nm Wavelength TX: 1310nm, RX: 1310nm RX: 1550nm 3dBm±1dBm to ROU Output power 3dBm±1dBm to ROU,OEU 7dBm±1dBm to ODU 7dBm±1dBm to ODU 3.1.3 Environmental specifications Parameter BIU, ODU, OEU Operating Temperature -10 Operating Humidity, non condensing - to +50°C ROU/AOR -10 to +50°C 5% to 90% 3.1.
3.1.
800MHz Public safety Typical Remarks Parameters TX RX Bandwidth 18MHz 18MHz System ripple ≤5dB ≤5dB Input Power level -20 to +10dBm ≤-50dBm Output power +30dBm +0dBm System Gain 43dB 50dB Gain Control range 18 to 43dB 30 to 50dB IM3 -13dBm - IP3 - +23dBm Noise figure - 15dB Total 1ROU 850MHz Cellular Typical Remarks Parameters TX RX Bandwidth 25MHz 25MHz System ripple ≤5dB ≤5dB Input Power level -20 to +10dBm ≤-50dBm Output power +30dBm +0dBm System Gain 43d
900MHz iDEN & Paging Typical Remarks Parameters TX RX Bandwidth 12MHz 6MHz System ripple ≤5dB ≤5dB Input Power level -20 to +10dBm ≤-50dBm Output power +30dBm +0dBm System Gain 43dB 50dB Gain Control range 18 to 43dB 30 to 50dB IM3 -13dBm - IP3 - +23dBm Noise figure - 15dB Total 1ROU 1900MHz PCS Typical Remarks Parameters TX RX Bandwidth 65MHz 65MHz System ripple ≤5dB ≤5dB Input Power level -20 to +10dBm ≤-50dBm Output power +30dBm +0dBm System Gain 50dB 50
1700MHz&2100MHz AWS-1 Typical Remarks Parameters TX RX Bandwidth 45MHz 45MHz System ripple ≤5dB ≤5dB Input Power level -20 to +10dBm ≤-50dBm Output power +30dBm +0dBm System Gain 50dB 50dB Gain Control range 25 to 50dB 30 to 50dB IM3 -13dBm - IP3 - +23dBm Noise figure - 15dB Total 1ROU 150MHz VHF Public safety Typical Remarks Parameters TX RX Bandwidth 38MHz 38MHz System ripple ≤5dB ≤5dB Input Power level -15 to +10dBm ≤-54dBm Output power +24dBm -4dBm System
450MHz UHF Public safety Typical Remarks Parameters TX RX 396~450MHz(54MHz) Bandwidth(Band1) 116MHz 116MHz 450~512MHz(62MHz) Band selection 380~434MHz(54MHz) Bandwidth(Band2) 116MHz 116MHz 434~496MHz(62MHz) Band selection System ripple ≤5dB ≤5dB Input Power level -15 to +10dBm ≤-54dBm Output power +24dBm -4dBm System Gain 39dB 50dB Gain Control range 14 to 39dB 30 to 50dB IM3 -13dBm - IP3 - +23dBm Noise figure - 7dB Confidential & Proprietary 23/139 Total 1ROU
Section4 System Configuration and Functions 4.1 BIU (BTS Interface Unit) 4.2 ODU (Optic distribution Unit) 4.3 OEU (Optic Expansion Unit 4.4 ROU (Remote Optic Unit) 4.
4.1 BIU (BTS S Interface e Unit) BIU provides TX X signals fro om BTS or BDA for four ODUs (O Optic Distrib bution Unit). This unit separates s R signals given RX g from ODUs O from each otherr per freque ency band. Figure 4.1 4 – BIU ou uter view 4.1.1 1 Specifica ations of BIU Item Spec. Remark Size 482.6((19”) x 221.5 5(5U) x 450 Mm Weightt 22.
4.1.2 2 Block dia agram of BIIU 4.1.3 3 BIU parts s Figure 4.2 – BIU mountting diagram m No.
Main Com/Div Unit 2 MCDU Combine 4EA downlink signal and divide 4EA signal to ODU Combine 4EA uplink signal and divide 4EA signal to MDBU Support VHF/UHF interface port Main Central Processor Unit Control and monitoring system status 3 MCPU Control and monitoring with RS232 Have an access to upper-level network through GSM or Ethernet 4 MPSU Main Power Supply Unit Input power: DC -48V, Output power: 9V, 6V Mother Board 5 M/B Provide signal interface and power for each unit Provide three ports for