Figure 5.10 – Installation flow diagram when AOR installs on wall
Put the enclosure with the M5 Wrench Bolt fixed on the fixing groove and fix the M5 Wrench
Bolts into the remaining fixing holes.
In this case, you will use 6EA of M5 Wrench Bolts in total except bolts used for the fixing groove.
ROU Rack Mount Installation
Like other units, AOR is designed to be inserted into a rack. The unit occupies about 4U of
space except cable connection.
In case that AOR is installed more close above/below existing ROU, temperature of ROU/AOR
increase ambient temperature, which increase ambient of AOR/ROU. Then, AOR/ROU’s
temperature is increased. Therefore, we recommend that AOR should be installed with at least
constant space from existing ROU(above 2U)
The following shows the installed diagram on rack with exisiting ROU