User's Manual

Confidential & Proprietary 115/139
Depneding on whether to use a port, output varies. Thus, make sure to turn OFF unused
ports.
The table below shows output power depneding on whether to use a port:
MDBU Band Output level (Composite
power)
No. of Max port (N)
700PS 23dBm-10*LOG(N) 2
700LTEC 23dBm-10*LOG(N) 2
800PS 23dBm-10*LOG(N) 2
850Cellular 23dBm-10*LOG(N) 2
900I+Paging 23dBm-10*LOG(N) 2
1900PCS 26dBm-10*LOG(N) 4
AWS-1 26dBm-10*LOG(N) 4
VHF 24dBm-10*LOG(N) 1
UHF 24dBm-10*LOG(N) 1
Check if the level of TX IN POWER is the same as the value measured through spectrum
(Within ±3dB). Use TX IN AGC function and automatically set internal ATT depending on input
level. ATT is automatically set based on -20dBm of input . The table below shows TX IN ATT
depending on TX IN POWER. For manual setting, you can set ATT depending on input
according to the table.
TX IN POWER TX IN ATT TX IN POWER TX IN ATT TX IN POWER TX IN ATT