User's Manual

Confidential & Proprietary 15/87
3.1 System specifications
3.1.1 Physical Specifications
Parameter BIU ODU OEU ROU
RF Connectors
4 SMA type, female
(Per MDBU)
2 SMA type, female
- 1N-type,female
External Alarm
connector
(Dry contacts)
Terminal block,3pcs - - -
Serial Interface
connector
1 RS-232 9-pin D-sub,
male
1 RS-232 9-pin
D-sub, male
1 RS-232 9-pin
D-sub, male
Fiber connector -
8pcs, SC/APC for
ROU
1 SC/APC for ODU
8 SC/APC for ROU
1 SC/APC for ODU
LED Alarm and
Status Indicator
MDBU Status
z Power On status
z ALM status
MCPU
z Power On status
z TX
Communication
z RX
Communication
z ALM status
MPSU
z Power On status
z DC ALM status
DOU1 Status
z LD status
z PD1/2/3/4
status
DOU2 Status
z LD status
z PD1/2/3/4
status
EWDM Status
z LD status
z PD status
DOU1 Status
z LD status
z PD1/2/3/4 status
DOU2 Status
z LD status
z PD1/2/3/4 status
System status
z Power on status
z TX
Communication
z RX
Communication
System status
z Power on status
z TX1
Communication
z RX1
Communication
z TX2
Communication
z RX2
Communication
z ALM status
AC Power - -
Normal Range :
120VAC 50/60Hz
Operating range
108~132VAC,50/60Hz
DC Power
Normal range: -48 VDC
Operating range:
-40.8 ~ -57.6VDC
-
Normal : -48 VDC
Operating range:
-40.8 ~ -57.6VDC
Power
consumption
168W
(Including ODU 4EA)
-
48W
(Including DOU2EA)
265W
(Including RDU 3EA)
Enclosure
Dimensions
482.6(19”) x 221.5(5U)
x 450
482.6(19”) x
43.6(1U) x 450
482.6(19”)
x 88.1(2U) x 450
420 x 530 x 258
Weight[Full Load] 22.25Kg 5.7Kg 9.3Kg 35.45Kg