SMDR SMDR-NH124 Installation and Operation Manual Document Reference: Version: V6.0 Document Status: Release 1 Issue Date: May.
REVISION HISTORY No. of Pages Version Issue Date Initials Details of Revision Changes V 1.0 Jan. 02, 2009 V 2.0 Oct. 23. 2009 Add RDU(VHF+UHF) V 3.0 Feb. 04. 2010 Add ADD ON V/UHF ROU V 4.0 Nov. 24. 2010 Add RDU E-VHF+UHF V 5.0 Feb. 21, 2011 LTE FULL BAND V 6.0 May. 22, 2012 Add 700LTEF+850C V 7.0 Dec.
Contents Section1 Safety & Certification Notice ............................................................... 10 Section2 System Overview.................................................................................. 13 2.1 General overview ........................................................................................ 14 2.2 System overview ........................................................................................ 15 Section3 System Specifications ..........................
.3.2 Block Diagram of OEU ......................................................................... 43 4.3.3 OEU parts.............................................................................................. 43 4.3.4 Function by unit ................................................................................... 44 4.3.5 Front/rear panels of OEU ..................................................................... 48 4.4 ROU (Remote Optic Unit) .............................................
.1.3 RF Interface at BIU ............................................................................... 72 5.1.4 MDBU insertion .................................................................................... 78 5.1.5 ODU Interface ....................................................................................... 79 5.1.6 Consumption Power of BIU ................................................................. 80 5.2 ODU Installation ......................................................
.1.4 Setting whether to use ROU/OEU at BIU .......................................... 120 6.1.5 ODU Operation at BIU ........................................................................ 122 6.2 ROU Operation ......................................................................................... 124 6.2.1 ROU Operation ................................................................................... 124 6.3 OEU Operation..........................................................................
Contents of Figure Figure 2.1 – Basic system topology .............................................................. 15 Figure 2.2 – Expansion system topology ...................................................... 16 Figure 4.1 – BIU outer view .......................................................................... 26 Figure 4.2 – BIU mounting diagram .............................................................. 27 Figure 4.3 – MDBU Outer Look.............................................................
Figure 4.22 – ERFM Outer Look ................................................................... 47 Figure 4.23 – OEU front panel Outer Look .................................................... 48 Figure 4.24 – Rear panel Outer Look ............................................................ 48 Figure 4.25 – ROU Outer Look ..................................................................... 49 Figure 4.26 – ROU Inner Look ...................................................................... 50 Figure 4.
Figure 5.10 – Installation flow diagram when AOR installs in the rack ......... 109 Figure 5.10 – AOR which is installed above of ROU ................................... 113 Figure 5.11 – AOR which is installed under of ROU ....................................
Section1 Safety & Certification Notice Confidential & Proprietary 10/139
“Only qualified personnel are allowed to handle this unit. Read and obey all the warning labels attached in this user manual” Any personnel involved in installation, operation or service of the SOLiD Technology repeaters must understand and obey the following: - Obey all general and regional installation and safety regulations relating to work on high voltage installations, as well as regulations covering correct use of tools and personal protective equipment.
-For PLUGGABLE EQUIPMENT, the socket-outlet shall be installed near the equipment and shall be easily accessible.
Section2 System Overview 2.1 General overview 2.
2.1 General overview SMDR-NH124 is a coverage system for in-building services delivering voice and data in high quality and for seamlessly. As a distributed antenna system, it provides analog and digital phone systems that are served in multiple bands through one antenna. The system covers general public institutions and private facilities. Shopping malls Hotels Campus areas Airports Clinics Subways Multi-use stadiums, convention centers, etc.
2.2 Signals with a plurality of service provider transmit simultaneously Support multi-oper operator in a band Low OPEX / CAPEX Compact design Upgradable design Easy installation and maintenance Web Based SNMP or GSM Modem or UDP support (Optional) System overview SMDR-NH124 NH124 is composed of devices given below. Basically, the system consists of BIU (BTS Interfcace Unit), ODU (Optic distribution Unit) and ROU (Remote Optic Unit).
Figure 2.2 – Expansion system topology Table 3.1 – System topology Charts System elements Optical Loss [dBo] Max.
Section3 System Specifications 3.1 System specifications 3.1.1 Physical Specifications 3.1.2 Optic wavelength and Laser power 3.1.3 Environmental specifications 3.1.4 Operating Frequencies range 3.1.
3.1 System specifications 3.1.
3.1.2 Optic wavelength and Laser power Parameter ODU OEU ROU West optic TX: 1310nm TX: 1550nm, RX: 1310nm TX: 1550nm RX: 1550nm East optic RX: 1310nm Wavelength TX: 1310nm, RX: 1550nm 3dBm±1dBm to ROU Output power 3dBm±1dBm to ROU,OEU 7dBm±1dBm to ODU 7dBm±1dBm to ODU 3.1.3 Environmental specifications Parameter BIU, ODU, OEU Operating Temperature -10 Operating Humidity, non condensing - to +50°C ROU/AOR -10 to +50°C 5% to 90% 3.1.
3.1.
700MHz Public safety (D Block) Typical Remarks Parameters TX RX Bandwidth 17MHz 17MHz System ripple ≤5dB ≤5dB Input Power level -20 to +10dBm ≤-50dBm Output power +30dBm +0dBm System Gain 43dB 50dB Gain Control range 18 to 43dB 30 to 50dB IM3 -13dBm - IP3 - +23dBm Noise figure - 15dB Total 1ROU 800MHz Public safety Typical Remarks Parameters TX RX Bandwidth 18MHz 18MHz System ripple ≤5dB ≤5dB Input Power level -20 to +10dBm ≤-50dBm Output power +30dBm +0dBm S
850MHz Cellular Typical Remarks Parameters TX RX Bandwidth 25MHz 25MHz System ripple ≤5dB ≤5dB Input Power level -20 to +10dBm ≤-50dBm Output power +30dBm +0dBm System Gain 43dB 50dB Gain Control range 18 to 43dB 30 to 50dB IM3 -13dBm - IP3 - +23dBm Noise figure - 15dB Total 1ROU 900MHz iDEN & Paging Typical Remarks Parameters TX RX Bandwidth 12MHz 6MHz System ripple ≤5dB ≤5dB Input Power level -20 to +10dBm ≤-50dBm Output power +30dBm +0dBm System Gain 43dB
1900MHz PCS Typical Remarks Parameters TX RX Bandwidth 65MHz 65MHz System ripple ≤5dB ≤5dB Input Power level -20 to +10dBm ≤-50dBm Output power +30dBm +0dBm System Gain 50dB 50dB Gain Control range 25 to 50dB 30 to 50dB IM3 -13dBm - IP3 - +23dBm Noise figure - 15dB Total 1ROU 1700MHz&2100MHz AWS-1 Typical Remarks Parameters TX RX Bandwidth 45MHz 45MHz System ripple ≤5dB ≤5dB Input Power level -20 to +10dBm ≤-50dBm Output power +30dBm +0dBm System Gain 50dB
150MHz VHF Public safety Typical Remarks Parameters TX RX Bandwidth 38MHz 38MHz System ripple ≤5dB ≤5dB Input Power level -15 to +10dBm ≤-54dBm Output power +24dBm -4dBm System Gain 39dB 50dB Gain Control range 14 to 39dB 30 to 50dB IM3 -13dBm - IP3 - +23dBm Noise figure - 7dB 136~174MHz Total 1ROU 450MHz UHF Public safety Typical Remarks Parameters TX RX 396~450MHz(54MHz) Bandwidth(Band1) 116MHz 116MHz 450~512MHz(62MHz) Band selection 380~434MHz(54MHz) Bandwidth(Ba
Section4 System Configuration and Functions 4.1 BIU (BTS Interface Unit) 4.2 ODU (Optic distribution Unit) 4.3 OEU (Optic Expansion Unit 4.4 ROU (Remote Optic Unit) 4.
4.1 BIU (BTS Interface Unit) BIU provides TX signals from BTS or BDA for four ODUs (Optic Distribution Unit). This unit separates RX signals given from ODUs from each other per frequency band. Figure 4.1 – BIU outer view 4.1.1 Specifications of BIU Item Spec. Remark Size 482.6(19”) x 221.5(5U) x 450 Mm Weight 22.
4.1.2 Block diagram of BIU 4.1.3 BIU parts Figure 4.2 – BIU mounting diagram No.
Main Com/Div Unit 2 MCDU Combine 4EA downlink signal and divide 4EA signal to ODU Combine 4EA uplink signal and divide 4EA signal to MDBU Support VHF/UHF interface port Main Central Processor Unit Control and monitoring system status 3 MCPU Control and monitoring with RS232 Have an access to upper-level network through GSM or Ethernet 4 MPSU Main Power Supply Unit Input power: DC -48V, Output power: 9V, 6V Mother Board 5 M/B Provide signal interface and power for each unit Provide three ports for