GENESISTM DAS Installation and Maintenance Version 0.0 Feb. 2019 ©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary.
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019 Copyright All rights are reserved ©2019 SOLiD. Confidential and proprietary. Information contained in this document is company private to SOLiD and should not be modified, used, copied, reproduced or disclosed in whole or in part without the written consent of SOLiD. Trademark Information No right, license, or interest to SOLiD trademarks is granted here.
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019 Revision History Revision Issue Date Section Changes ©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary.
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019 Contents Safety & Certification Notice .................................................................................. 7 System Overview ..................................................................................................... 9 2.1 2.2 Purpose ......................................................................................................................................... 9 System Overview .....................................
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019 List of Illustrations Figure 2.1 GENESISTM Network Topology ................................................................................................. 11 Figure 4.1 LRN Front, Side and Rear Views ............................................................................................... 16 Figure 4.2 LRN Appearance .......................................................................................................................
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019 Glossary of Terms Acronyms and abbreviation used in this manual are shown in the table below.
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019 Safety & Certification Notice “Only qualified personnel are allowed to handle this unit.
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019 Rotating fan Blade Can cause serious injury or pain. Keep hands clear. Turn off and lock-out unit before servicing. C AUTION Do Not Open Except at Approved Field Force Protective Work Station. ©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary.
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019 System Overview GENESISTM is a coverage system for indoor and outdoor services delivering voice and data in high quality and for seamlessly. As a distributed antenna system, it provides analog and digital phone systems that are served in multiple bands. The system covers general public institutions and private facilities.
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019 The system is featured with the followings: Universal One Digital transport DAS platform Cover small to large venues with Low power remotes Common Head-End for various remote types Low power remotes to transport signals over an optical fiber SOLiD GENESISTM is a robust, flexible, expandable, and customizable cellular coverage solution for multiple operators and technologies as universal platform.
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019 2.2.1 System Components and Network Topology GENESISTM product series are that one common head-end delivers a more flexible network configuration. Universal Point of Interface (UPOI): Attenuate high power signal from RAN and transport into DAU Distribution & Aggregation Unit (DAU): Interface with analog RANs.
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019 2.2.2 System Capacities UPOI can support up to eight (8) interface module slots and each slot supports three (3) input ports. DAU can have up to six (6) RF interface module slots and each slot supports four (4) input ports. DAU can support up to two (2) Expansion DAUs. Adding two (2) Expansion DAUs to the main DAU, a system can support up to seventy-two (72) cell interfaces.
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019 System Specifications Item Specification Frequency Band Instantaneous Bandwidth Technology Remark 700FB 8085 1900 AWS13 2300W 2500TDD 39MHz 32MHz 65MHz 70MHz 10MHz 190MHz GSM, UMTS, GSM, UMTS, LTE, CDMA LTE, CDMA UMTS, LTE LTE LTE LTE Transmission Capacity 10Gbps Transmission Distance <10km@Optic, <100m@Power Cable(AWG 14 to 24) VSWR < 1.5 : 1@DAU, <1.8 : 1@LRN Uplink Frequency Error ±0.01ppm System Delay < 8usec, 1.
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019 Operating Temp. -5 ~ +45°C -5 ~ +45°C 19” x 3U x 475 19” x 3U x 475 64 Watt, w Weight, kg Size(WxHxD), mm Normal Noise, dBA -5 ~ +45°C 19” x 1U x 19” x 1U x 19” x 1U 390 x 300 x 74 420 371.4 x 374 (8.7ℓ) 61 NA 60 65 NA 25 370 36 55+800(LRN) 800 X 3 75 31 17.5 4.36 4.15 10.1 7.5 Item Ripple -5 ~ -5 ~ +45°C +45°C -25 ~ +45°C Specification < 4dB UPOI Input level DAU Remark Peak to peak +47 ~ +30dBm Max.
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019 Item Ripple Specification < 4dB Input Level Output Power System Gain Gain Control EVM Noise Figure Remark Peak to peak Nominal -40dBm Max. -38dBm @ No- destructive by ALC function Duplexed port -15dBm/total Simplex port -35dBm/total Duplexed port 30dB Simplex port 10dB 0 ~ 50dB RN per band DAU RN to DAU DAU LTE < 8% UMTS < 12.5% 64QAM < 14dB ©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary.
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019 System Configuration and Functions The LRN is active modular and multi-band upgradeable antenna unit. It supports four (2) sub-modules which are replaceable in a SOLiD certified facilities by SOLiD certified personnel. The mix of service bands can be achieved, for example, six (6) different bands are available. The composite RF power per band is 15dBm(below 1GHz), 20dBm(upper 1GHz) and 17dBm(2300W Band). Figure 4.1 LRN Front, Side and Rear Views 4.
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019 4.1.2 LRN Functions and Description The LRN provides highly flexible combinations of service bands and sectors. Typical configurations of LRNs are six (6) band SISO.
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019 LRN includes all components in the enclosure below. The following table shows LRN components, functions and quantities.
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019 LPMU SPECIFICATION The LPMU amplifies downlink RF signal and then filters the signal, and for uplink, it filters and amplifies uplink signals in sequential order. The following table shows LPMU specification.
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019 4.1.3 LRN Front and Rear Panel 4.1.3.1 Front Panel Figure 4.3 LRN Front Panel View No ① 4.1.3.2 Item ANT Description External antenna interface port Rear Panel Figure 4.
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019 4.1.4 LRN Installation The following table shows the required accessories and tools for installing LRN. Installation Items LRN Enclosure Ext.
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019 Outlook Mounting bracket kit The following procedures are to install each mounting bracket. A. QUICK-LOCK MOUNTING BRACKET 1. Mark the position of the drilling holes on the wall or ceiling to match the holes of the wall bracket. 2. 3. 4. 5. Drill 4(four) holes at the marked position. Secure the wall bracket to the wall or ceiling using the 4(four) M6 anchor sets. Slide the LRN into the wall bracket and lift it up to be caught on the bracket.
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019 B. CEILING MOUNTING BRACKET 1. 2. 3. 4. Combine LRN and ceiling mount with 4(four) M4 screws. Position the LRN in the direction shown below. Adjust the ceiling mount to the ceiling frame interval you want to install. Tighten the ceiling frame with M4 and M6 screws in the screw hole of the ceiling mount. ©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary.
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019 LRN POWER CABLING The LRN can use DC power supply from HOU. Power cables DC are not provided because different length of cables depends on field situation and different types of jack in each country. Figure 4.6 LRN Power Cabling The recommended power cables (AWG 14 to 24) is dependent on each country. User can seek easily in the market. ©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary.
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019 LRN OPTICAL FIBER C ABLING LRN has total two SFP ports, one SFP ports is for HOU and the other SFP ports is for daisy chain LRN. The following shows SFP port and name Figure 4.7 LRN SFP Ports The following table shows SFP type each SFP ports on the LRN based on mode (LRN or Daisy chain LRN).
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019 Do not stretch the fiber. Make sure the bend radius of the fiber is not less than 2inches(5.08cm) User can add or remove SFP modules in LRN without powering off the system. To insert an SFP module: Holding the SFP module by its sides, insert the SFP module into the port on the LRN Slide the SFP module into the port until you hear it click. If the SFP module has a handle, push up on the handle to secure the SFP module.
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019 The following shows optical fiber based on SFP type No SFP Types Optical fiber 1 Connector/Ferrule type Remark LC/UPC SFP-10G-SR 2 optical fiber ©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary.
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019 System Operation LRN consists of digital board and RF module. Based on components, all parameters are displayed. LRN PARAMETERS LRN Digital board receives optical data from HOU over optical cable. And then convert into RF signal. System information shows a lot of CPU firmware version, temperature, serial number, and so on.
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019 ① ② ③ ④ Band information DL Output power DL/UL Amp on/off UL Input power ©2019 SOLiD, Inc. All Rights Reserved. Confidential & Proprietary.
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019 FCC/IC User Warning FCC PART 15.105 STATEMENT This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
GENESISTM DAS Operation Manual - Version 0.0 – Jan. 2019 This radio transmitter (identify the device by certification number, or model number if Category II)has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.
FCC Booster warning Part 90 and Part 20 Signal Boosters. THIS IS A 90.219 CLASS B DEVICE WARNING. This is NOT a CONSUMER device. It is designed for installation by FCC LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express consent of an FCC Licensee to operate this have an FCC LICENSE or express consent of an FCC Licensee to operate this device. You MUST register Part 90 Class B signal boosters (as defined in 47 CFR 90.219) online at www.fcc.gov/signal-boosters/registration.