Alliance-TR_N2ROU_CALA for Mexico(Remote Unit) User Manual SOLiD, Inc.
REVISION HISTORY Version Issue Date Section Description V 1.0 April 27, 2020 All Original Preface Technicians using these manuals should have completed the SOLiD Certification Program. SOLiD also recommends technicians be familiar with the concepts of fiber optic cabling, networking and wireless communication technologies, and SNMP.
Contents Section1 1.1 Safety & Certification Notice ............................................................................... 4 Section2 2.1 Overview ........................................................................................................... 7 2.2 N2ROU .............................................................................................................. 8 Section3 3.1 Functional Description .......................................................................................
Section1 1.1 Safety & Certification Notice “Only qualified personnel should handle the DAS equipment. Any person involved in installation or service of the DAS should understand and follow these safety guidelines.” - Obey all general and regional safety regulations relating to work on high voltage installations, as well as regulations covering correct use of tools and personal protective equipment. - The power supply unit in repeaters contains dangerous voltage level, which can cause electric shock.
- For pluggable equipment, make sure to install the socket outlet near the equipment so that it is easily accessible. - Certification FCC: This equipment complies with the applicable sections of Title 47 CFR Parts 15,22,24, 27 and 90 UL/CUL: This equipment complies with UL and CUL 1950-1 Standard for safety for information technology equipment,including electrical business equipment FDA/CDRH: This equipment uses a Class 1 LASER according to FDA/CDRH Rules.
- Prior to equipment use the service must be registered with the FCC. This can be done through the FCC’s website at https://signalboosters.fcc.gov/signal-boosters/. - Access can only be gained by SERVICE PERSONS or by USERS who have been instructed about the reasons for the restrictions applied to the location and about any precautions that shall be taken; and - Access is through the use of a TOOL or lock and key, or other means of security, and is on trolled by the authority responsible for the location.
Section2 2.1 Overview The N2ROU is a coverage system for in-building services delivering voice and data in high quality and for seamlessly. As a distributed antenna system, it provides analog and digital phone systems that are served in multiple bands through one antenna. The system covers general public institutions and private facilities. Shopping malls Hotels Campus areas Airports Clinics Subways Multi-use stadiums, convention centers, etc.
Flexibility & Scalability Support fiber-optic ports up to 60 Clustering multiple-buildings (campus) as one coverage Option structures Modular frequency upgrade Multi-Band, Multi Operator Signals with a plurality of service provider transmit simultaneously Support multi-operator in a band Low OPEX / CAPEX Compact design Upgradable design Easy installation and maintenance 2.
Section3 3.1 Functional Description The following figure shows the block diagram of N2ROU. The N2ROU has four different diagrams based on optional modules. The diagram shown below is the first one with the default combination. Figure 3.
The diagram below shows the 4 bands(SISO) combination and 2 bands(MIMO). combination 4 base bands with 2 additional bands. Figure 3.
3.2 N2ROU Component The following figure shows internal configuration of the N2ROU fully equipped with frequency bands. Figure 3.5 – Internal View of Remote Unit The N2ROU receives TX optical signals from Head-End and converts them into RF signals. The converted RF signals are amplified through High Power Amp in a corresponding RDU, combined with Multiplexer module and then radiated to the antenna port.
The following table describes components of N2ROU. Unit Description Remote Drive Unit N2RDU Amplify TX signals Amplify RX signals Remove other signals through BPF Remote AC Power Supply Unit RPSU (AC) Input power: 90~280 VAC Output power: +29.
3.3 Dimension Figure 3.6 – Remote Unit Dimension ITEM SPECIFICATION REMARK Dimensions (WxHxD) 18.5”x16.5" (10 RU) x 10.2” (470mm x 420mm x 260mm) Including Bracket Weight Max. 69.44 lbs (31.5kg) for base model, 4 bands Max. 72.75 lbs (33kg) for 5 bands Max. 80.46 lbs (36.
Section4 4.1 Installation This chapter describes how to install each unit and optical cables. It also explains how to install shelves or enclosuers of each unit, power cabling method and optical cabling and RF interface. Required accessories and tools for installation are list up in the below table. 4.
of MIMO. N2RDU_L700A Module M4 Screw (6EA) I/O Cable (1EA) TX IN RF Cable (1EA) Base RDU to Option Expansion of N2RDU_L700A (Not support) RDU RX OUT RF Cable #1 ○ Screwdriver (+) (1EA) Base RDU to Option RDU TX RF Cable (1EA) L700A RDU to MUX RX RF Cable (1EA) L700A RDU to MUX N2RDU N2RDU_1900P_M Installation Module (Optional N2RDU_AWS13_M bands) Module For more details, refer to 4.3.5.
to L2600F_M Casecade RX RF Cable(1EA) AWS13_M/1900P_M to L2600F_M MUX RF Cable (1EA) MUX to ANT Port TX RF Cable (1EA) 1900P_M/AWS13_B RDU to MUX RX RF Cable (1EA) 1900P_M/AWS13_M RDU to MUX TX RF Cable (1EA) L2600F_M RDU to MUX RX RF Cable (1EA) L2600F_M RDU to MUX For RF Adaptor MIMO Antenna [4.3-10 DIN(F) type to SMA(F) type Adaptor] #0 Screw Connection (Optional) driver (+) M3 Screw (4EA) more details, refer to 4.3.6. For Inner Data Interface Cable (1 EA) Connection [0.
4.3 Install N2ROU 4.3.1 Install N2ROU The N2ROU uses a unibody enclosure that is NEMA 4 (IP66) certified to withstand water and dust intrusion. It can be mounted on a pole, wall, or rack. Basically wall-mounted bracket for N2ROU is included. Figure 4.
Figure 4.2 – N2ROU Wall Mount Dimensions Figure 4.
N2ROU Wall Mount Procedure The enclosure comes with the bracket for wall mounting. It doesn’t need to remove the bracket to install the enclosure, simply install and tighten 4 mounting bolts to secure the unit. First, install 2 of M12 mounting bolts roughly half way into the wall. Mount the enclosure and tighten the bolts. Second, tighten the remaining M12 mounting bolts under the enclosure and secure the unit tightly. Figure 4.
N2ROU Components N2ROU has the following components: No.
4.3.2 N2ROU Power Cabling AC Power The N2ROU supports only AC 120V input power and only a single type of power cable is provided. The pin discription of AC port is as below. Pay attention to the correct polarity. AC Power Port MS Connector No. Name Description A AC_H AC Hot B AC_N AC Neutral C N.C Not Connected D F.G Frame Ground Check if the connection is the same as one seen in the table above and make sure to turn the power ON.
4.3.3 N2ROU Ground Cabling The grounding terminal is located at the bottom of N2ROU enclosure fixed by an M6 screw. Compression terminal is attached already when it is delivered. The recommended thickness of cable is AWG#6 copper grounding wire. Figure 4.7 – Location of Ground Terminal The specification of compression terminal is as follows. Figure 4.
The required part number is JOCO 0102-RS06 that supports AWG 6. To install the grounding cable, follow the steps below. Figure 4.9 –Installing Ground Terminal The procedures are 1. Loosen two M6 screws and then take compression terminal off 2. Insert AWG#6 grounding wire into terminal, and then compress a terminal using the tool 3. Assemble the terminal with 2xM6 screws 4.
4.3.4 Optical Cabling The Optical connector is located at the bottom of the N2ROU. Optical cable can be connected by using its connectors. Figure 4.10 –Optical Connector Refer to the figure below for detailed information. The figure is based on LC type, but can be applied to SC type as well.
4.3.5 Mounting N2RDU (Optional Modules) The N2ROU has the basic modules as shown on the left side of the enclosure (see the figure below) and the maximum of two optional remote units can be installed on the right. Various combinations can be configured based on different services and conditions. Figure 4.
Mounting of N2RDU_1900P_M+ N2RDU_L2600F_M or AWS13_M+ N2RDU_L2600F_M (MIMO Band Expansion) N2RDU_1900P_M, N2RDU_AWS13_M and N2RDU_L2600F_M module can be installed in the N2RDU as an optional module in the pink box shown in the figure below. It can be installed with 12 screws included in the package. Figure 4.
Refer to the figure below for cabling in order to service 1900P_M + L2600F_M or AWS13_M + L2600F_M Band Expansion. Figure 4.
4.3.6 MIMO Antenna Connection (Optional) To support MIMO service, MIMO Antenna connection is required. Figure 4.22 – Installing MIMO Antenna Adaptor The procedures are 1. Remove the dummy cover from the ANT2 port. 2. Install 4.3-10 DIN(F) to SMA(F) Adaptor with the screws included in the package.
Section5 5.1 Specifications Mechanical Specification Mounting Type Wall or rack mounting Connectors Craft Port Antenna port type: 4.
Optics SC/APC (Step Ferrule) Laser Diode/Photo Diode 1550nm/1310nm (Coaxial Type) Optical Loss Max 5dBo (4-port optical module); Max 10dBo (1-port optical module) 5.
FCC Part 15.105 statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
RSS-GEN, Sec. 7.1.2 – (detachable antennas) (Max. antenna gain : 17 dBi) This radio transmitter (identify the device by certification number, or model number if Category II)has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated.