ALLIANCE_PS2ROU User Manual Confidential & Proprietary 1/27
REVISION HISTORY Version Issue Date V 1.0 Sep. 01, 2019 No. of Pages Initials Details of Revision Changes Original Technical Support SOLiD serial numbers must be available to authorize technical support and/or to establish a return authorization for defective units. The serial numbers are located on the back of the unit, as well as on the box in which they were delivered. Additional support information may be obtained by accessing the SOLiD Tehcnology, Inc. website at www.solid.co.
Contents Section1 Safety & Certification Notice ....................................................................... 5 Section2 System configuration and Functions ............................................................. 8 2.1 PS2ROU (Public Safety 2W Remote Unit) ............................................................ 8 2.1.1 Specifications of PS2ROU ............................................................................ 9 2.1.2 Block Diagram of PS2ROU ..............................
Contents of Figure Figure 3. PS2ROU .............................................................................................. 8 Figure 4. PS2ROU outer Look .............................................................................. 9 Figure 5. PS2ROU Block diagram ....................................................................... 10 Figure 6. Inside of Remote Unit ......................................................................... 11 Figure 7. PS2RDU Outer Look ...........................
Section1 Safety & Certification Notice “Only qualified personnel should handle the DAS equipment. Any person involved in installation or service of the DAS should understand and follow these safety guidelines.” - Obey all general and regional installation and safety regulations relating to work on high voltage installations, as well as regulations covering correct use of tools and personal protective equipment.
- For pluggable equipment, make sure to install the socket outlet near the equipment so that it is easily accessible. - A readily accessible disconnect device shall be incorporated external to the equipment. - This power of this system shall be supplied through wiring installed in a normal building.
Prior to equipment use the service must be registered with the FCC. This can be done through the FCC’s website at https://signalboosters.fcc.gov/signal-boosters. - Certification FCC: This equipment complies with the applicable sections of Title 47 CFR Parts 90(Class B) - Use of unauthorized antennas, cables, and/or coupling devices not conforming with ERP/EIRP and/or indoor‐only restrictions is prohibited. - Home/ personal use are prohibited.
Section2 System configuration and Functions 2.1 PS2ROU (Public Safety 2W Remote Unit) PS2ROU receives TX optical signals from ODU and converts them into RF signals. The converted RF signals are amplified through Power Amp in a corresponding PS2RDU band combined with UDCU, PAU and Cavity Filter, and then radiated to the antenna port.
2.1.1 Specifications of PS2ROU Figure 2. PS2ROU outer Look Spec. Item Remark PS2ROU 700PS_FN +33dBm The rated mean output Power 800PS +33dBm per band VHF/UHF +24dBm 900I_PA +33dBm 700PS_FN 17MHz FCC : 758~775MHz ISED : 758~775MHz The nominal downlink FCC : 851~861MHz 800PS 10MHz bandwidth ISED : 851~861MHz FCC: 150~174MHz Confidential & Proprietary VHF 38MHz UHF 132MHz 9/27 ISED : 138~174MHz FCC: 406.
ISED : 406.1~430MHz 450~470MHz FCC : 929~930MHz 935~940MHz ISED : 929~930MHz 900I_PA 6MHz 932~932.5MHz 932.5~935MHz 935~940MHz 700PS_FN 17MHz 788~805MHz The nominal Uplink 800PS 10MHz 806~816MHz bandwidth VHF 80MHz 136~216MHz UHF 132MHz 380~512MHz 900I_PA 6MHz 896~902MHz 2.1.2 Block Diagram of PS2ROU 2.1.2.1 PS2ROU block diagram Figure 3.
2.1.2.2 ROU inner look Figure 4.
2.1.2.3 PS2ROU part list Unit Description Remote Drive Unit PS2RDU Amplify TX signals Amplify RX signals Remove other signals through BPF Remote AC Power Supply Unit RPSU (AC) Input power: 100~240 VAC Output power: +29.2 VDC Remote DC Power Supply Unit RPSU (DC) Input power: -42 ~ -56 VDC Output power: +29.
2.1.3 Function by unit 2.1.3.1 Public Safety 2W Remote Drive Unit (PS2RDU) When receiving TX signals from each band throughgh Remote Optic, PS2RDU filters the signals and amplifies them with High Power Ampifier. The unit also filters RX signals given throughgh amplifies them to send the signals to Remote Optic.In the unit, there is ATT to adjust gain. PS2RDU consist of UDCU, PAU like below figure and all modules are merged with one package. Figure 5.
ISED : 758~775MHz 800PS > FCC : 851~861MHz ISED : 851~861MHz FCC : 929~930MHz 935~940MHz ISED : 929~930MHz 3 PS2RDU_90I_PA Single band 896~902MHz 932~932.5MHz 932.
2.1.3.2 PS2ROU Power Supply AC Power Supply The PS2ROU supports only AC 100~240V input power and only a single type of power cable is provided. The pin discription of AC port is as below. Pay attention to the correct polarity. Check if the connection is the same as one seen in the table above and make sure to turn the power ON. The figure below is the AC power cable that comes with the unit. Figure 4.
DC Power The N2ROU supports only DC -48V input power and a single type of power cable is provided. The pin discription of DC port is below. Pay attention to the correct polarity. Check if the connection is the same as one seen in the table above and make sure trn the power ON. The figure below is the DC power cable included in the package. Figure 4.6 – DC Power Supply 2.1.3.3 Remote Optic(ROPTIC) Remote Optic converts optical signals into RF signals and performs vice versa.
Figure 6. R OPTIC Outer Look 2.1.3.4 Remote Central Processor Unit (RCPU) RCPU can monitor and control each module of PS2ROU. This unit receives and analyzes upper communication data from Remote Optic and reports the unit's own value to upper devices. At the front of the module, it has LED indicator to show system status, letting you check any abnormalities at a time. At the same front, it also has communication LED Indicators to show communication status with upper devices.
2.1.3.5 Multiplexer Multiplexer it called combine unit(CU) works as a module to combine or distribute multiple signals into one or two antennas. This device has a port to combine multiple signals. You need to connect input and output ports of RDU throughgh a corresponding port. Figure 8.
2.1.4 Bottom of PS2ROU 2.1.4.1 Functions Figure 9. The Bottom Look of PS2ROU No Port PS2ROU Remark SC/APC, Waterproof 1 Optical Port 1EA 2 Power Port 1EA The cable is directly inserted in port hall.
Section3 System Installation 3.1 PS2ROU Installation This chapter describes how to install each unit and optical cables, along with power cabling method. In detail, the chapter describes how to install shelves or enclosuers of each unit, Power Cabling method and Optic Cabling and RF Interface. Furthermore, by showing power consumption of modules to be installed in each unit, it presents Power Cabling budget in a simple way.
3.1.2 PS2ROU Enclosure installation PS2ROU is designed to be water- and dirt-proof. The unit has the structure of one-Body enclosure. It satisfies water-proof and quake-proof standards equivalent of UL Type4X. The way to install for both PS2ROU has same method. Basically PS2ROU is attached with wall mountable bracket. PS2ROU can be mounted into either of wall or on a pole. Figure 10.
Figure 11. Dimension used to install PS2ROU on the WALL 3.1.3 PS2ROU Wall Mount Installation PS2ROU’s installation bracket is attached on Enclosure when is delivered. It doesn’t need to remove bracket to install enclosure. simply after installing 4 of M12 mounting bolts, secure 4 mounting bolts tightly. First, install 2 of M12 mounting bolts roughly half way on the enclosure and install enclosure over the bolts and secure tightly.
3.1.4 PS2ROU components PS2ROU has the following components: No. Common Part Unit Remark Enclosure Including Wall mounting bracket 1EA RCPU - 1EA R_OPTIC With SC/ACP adaptor 1EA,optional RPSU AC 100~240V or DC -48V 1EA This integrated combiner unit combines all bands 1EA, for output to a single antenna connection.
3.1.4 PS2ROU Optical Cable The Optical Connector is located at the bottom of Remote Unit enclosure fixed. Optical Cable can be connected by using connectors. The specification of compression Optic Connector is like below. The way to install the Optical cable comply with below procedures The procedures are Figure 12.
3.1.5 PS2ROU EXTERNAL ALM IN/OUT Port cabling The ALM IN/OUT Connector is located at the bottom of Remote Unit enclosure fixed. Cable can be connected by using connectors. Figure 13. Location of ALM IN/OUT Connector 3.1.6 Mounting of PS2RDU PS2ROU has slots to enable up to four PS2RDU modules to be mounted in it. You can mount a PS2RDU into designated slot surely and should install each PS2RDU into its designated location as shown in the installation diagram on the door of enclosure.
FCC/IC User Warning FCC PART 15.105 STATEMENT This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
RSS-GEN, SEC. 7.1.2 – (DETACHABLE ANTENNAS) This radio transmitter (identify the device by certification number, or model number if Category II)has been approved by Industry Canada to operate with the antenna types listed below with the maximum permissible gain and required antenna impedance for each antenna type indicated. Antenna types not included in this list, having a gain greater than the maximum gain indicated for that type, are strictly prohibited for use with this device.