2" Dedicated Well Cap Assembly (#116244)
Includes the Well Cap Base, Cap, Insert and Support Hanger
Bracket (4" Adaptor also available (#110235))
1. Wrap the top end of the Pump cable around the support
hanger bracket, inserting the cable into the cutouts of the
bracket to secure. Leave about 3” of slack in the Pump cable
(top end has connectors for the Controller) above the top of the
bracket.
Note: The holes in the bracket can accommodate twist ties or zip ties to
secure the cable to the bracket, if desired.
2. Just above the hanger bracket, slip the Pump cable through
the pass-through in the side of the well cap insert and into the
opening (tubing pushfit connection on the insert facing up).
Line up the insert with the hanger bracket, to avoid twisting
the cable.
3. Connect the sample tubing from the Pump to the tubing barb
on the bottom of the well cap insert. Ensure the tubing is
pushed all the way onto the tubing barb.
4. Slide the well cap base onto the well casing.
5. Lower the pump assembly down the well until the support
hanger bracket seats on the shoulder of the well cap base.
6. Push a short length of 3/8" OD sample tubing into the pushfit
connection on the top of the well cap.
7. Connect the Controller to the Pump cable connector and
operate the 12V Pump in the same manner as described on
Page 1.
Note: While sampling, the red plug can be removed from the opening in the
well cap insert to accommodate other monitoring equipment, such as
a Solinst Water Level Meter or Levelogger.
8. Once finished sampling, release the sample tubing from the
pushfit connection by pushing down on both sides of the top
ring and pull the tubing out.
9. Secure the well cap to the well cap base. Attach an optional
padlock if needed.
Sample Tubing
Pusht Connection
Pass-through for
Pump Cable
Well Cap Base
Well
Cap
Insert
Opening for
Monitoring
Equipment
3/8" OD
Sample Tubing
Pump Cable
(130 ft, 100 ft, 75 ft,
50 ft & 25 ft lengths
available)
Support Hanger
Bracket
Sample Tubing
Pump Cable
Connector
Controller
Connector
Eyebolt
Sample Tubing
Barb