somfy.
Elixo 500 24 V GENERAL INFORMATION 2 SAFETY 2 General information Safety instructions Motorising an existing gate 2 2 3 PRODUCT DESCRIPTION 3 Composition of the kit Description of the motorisation General motor size Area of application General view of a standard installation INSTALLATION 3 3 3 4 4 4 Assembling the release lever Disengaging the motorisation Installing the motorisation Wiring 4 4 5 6 QUICK COMMISSIONING 7 Installer interface Language selection Memorising remote controls Self-
Elixo 500 24 V GENERAL INFORMATION EN This product, installed in accordance with this guide, complies with EN 12453 and EN 13241-1 standards. Somfy hereby declares that this product complies with the essential requirements and other relevant provisions of Directive 1999/5/EC. A Declaration of Conformity is available at the web address www.somfy.com/ce (Elixo 500 24 V). Suitable for use in EU, CH and NO.
Elixo 500 24 V Regularly check the condition of the gate. Gates in poor condition must be repaired, reinforced or even replaced. Check that the various motorisation component’s screws and fittings are correctly tightened. EN Before carrying out any work on the installation, switch off the power supply and/or disconnect any backup batteries. Motorising an existing gate Carry out a stress test with a measuring device which conforms to the requirements set out on in clause 5.1.1 of standard EN 12445.
Elixo 500 24 V Area of application Sliding gates up to 500 kg and carrying out 30 operations per day. EN To ensure the safety of all equipment and persons, respect the information given in the table: For a gate weighing ... 0 to 300 kg use ... a passive rubber profile on the end of the gate Ref. 9014597 300 to 500 kg a passive rubber profile on the end of the gate 9014598 If using a different rubber profile to those listed above, ensure that the installation conforms with current regulations.
Elixo 500 24 V Installing the motorisation The motor mounting kit provided is to be used on a concrete base. For all other types of mounting, use the appropriate fittings.
Elixo 500 24 V Fitting the end limit brackets SX [1] Manually move the gate to the open position. DX [2] Position a bracket onto the rack so that it activates the motor end limit contact. EN [3] Screw the bracket onto the rack. [4] Manually move the gate to the closed position then repeat steps 2 and 3 to fit the second bracket to the rack.
Elixo 500 24 V Connection to the power supply To connect the motor to the power supply, use a standard, multicore cable with a minimum cross section of 3x1.5 mm². N L 33 34 EN Inputs 23, 24 and 25 must be bridged to terminal 21 if they are not used to connect a safety device.
Elixo 500 24 V Memorising the remote controls To memorise a remote control: .......2 min........ EN [1] Press the PROG button on the control unit for 2 seconds. The red indicator light will come on. 2s [2] Press a channel on the remote control to which the motorisation will be linked within 2 minutes. The red indicator light flashes, the remote control has been memorised. If this procedure is carried out using a channel which has already been memorised, this channel will be cleared.
Elixo 500 24 V If self-learning is correct, OK is displayed on the motorisation screen. If self-learning has failed, KO is displayed on the motorisation screen. Check the following before restarting self-learning: • the gate runs correctly, EN • there is nothing obstructing the photoelectric cells (if fitted). If self-learning is interrupted, return the gate to the closed position and restart self-learning. If the slowing down speed is subsequently changed, self-learning must be carried out again.
Elixo 500 24 V Reflex photoelectric cell Without autotest EN With autotest 8 7 6 5 4 3 2 1 9 10 11 12 13 14 Ref. 9014896 Activate the cell autotest function: tESt Phot to ON in the LoGIc menu. On the cell, set the DIP switch1 to ON and the DIP switch2 to OFF. Deactivate the cell autotest function: tESt Phot to OFF in the LoGIc menu. On the cell, set the DIP switch1 and the DIP switch2 to ON.
Elixo 500 24 V PARAMETER SETTING Menu [Display] Value By default EN If the parameters are changed after self-learning has been carried out, ensure the installation conforms to all relevant standards. Comments Language [LAnGUAGE]: to select the language for displaying information on the control unit screen. French [Fra] English [Eng] Spanish [Esp] German [Deu] Italian [Ita] Fra Self-learning [AutoSet]: to start self-learning for the gate travel.
Elixo 500 24 V Menu [Display] EN START-CLOSE selection [StArt - cLoSE] Pedestrian opening [PEdEStrIAn] Value By default Comments ON: the input between terminals 21 and 22 operates as CLOSE. OFF: the input between terminals 21 and 22 operates as START. ON: Activates the pedestrian opening. OFF: Deactivates the pedestrian opening. OFF CLOSE: the device connected between terminals 21 and 22 only enables the gate to be closed.
Elixo 500 24 V During the opening and closing phases, four figures separated by a dot are displayed on the screen, for example 35.40. The figures are updated whilst the gate is moving. They represent the actual torque used (35) and the torque set during the selflearning procedure (40). These values enable the torque entry to be corrected.
EN Elixo 500 24 V 14 Copyright © 2008 Somfy SAS. All rights reserved.