User's Manual

35en
Deleting all learned radio codes
Press the learn button (1) and hold it until
the LED (Radio) initially blinks for five seconds,
and then slowly blinks for ten seconds,
and subsequently blinks quickly for ten seconds.
When the LED (Radio) turns off, all radio codes are
deleted.
If the learn button is released prior to this, the radio
codes are not deleted.
Programming the drive
The drive controller automatically detects the required force
for opening and closing of the door automatically during the
following drive programming procedure. The force values that
are learned in are only high enough so that the drive opens
and closes the door without interruption. If an obstacle (e.g. a
person or a vehicle) blocks the door’s movement, the drive is
able to detect this since more force is required than the
stored value. In this case, the drive stops the door’s move-
ment for safety reasons. If this happens during the “Door
Close” movement, the door is subsequently opened com-
pletely.
For every run of the door, the controller compares the stored
force values (for opening and closing of the door) with the
actual value required and automatically adjusts the stored
values upon reaching the end position.
2
1
14
15
16
Radio
Power
Status
Safety
Command
Reset
LearnLearnLearn
13
3
4
5
6
Radio
Power
Status
Safety
Command
Reset
LearnLearnLearn
111
Close the door by hand.
Pull once on the emergency release cord grip (N) to stop
the carriage (1).
Move the carriage back and forth slightly to ensure that it is
stopped in position.
Plug the power plug into the power outlet or switch on the
circuit breaker or fuse that supplies the drive with electric-
ity.
The drive’s lighting blinks when the drive is fist connected
to the mains supply. This indicates that the drive is ready to
learn the code.
Press the Reset button on the controller housing (1) until
the lighting LED “Status“ goes out. The LED “Status“ blinks
while being pressed.
Release the Reset button. The lighting (2) and the LED
“Status“ blink.
N
1
Setting-up operation