Operating Instructions and Installation Instructions

Installation
t
– 12
Installation (example: installation
variant B)
ATTENTION!
Use a surefooted and stable ladder.
THP
THP
11
5 -
65mm
min. 35mm
THPTHP
11
5 -
65mm
min.
35mm
11
max. 30°
NOTE!
If the distance between the ceiling and the bottom edge of the
C-rail is greater than 245 mm, extend the ceiling suspension
bracket with perforated strip steel.
NOTE!
Please observe that the distance may possibly be reduced if
a door handle is attached to the middle of the door. The door
must be able to run freely.
Determine the door's highest point (THP):
Open the door and measure the closest distance (min. 35 mm)
between the top edge of the door and the ceiling. The distance between
the THP and the bottom edge of the C-rail must be between 5 mm and
65 mm; the angle of the door arm must be max. 30°.
12
S
30
min.15
30
15
15
D
½
½
½
½
VMVM
13
NOTE!
If installing on the ceiling (D), space the drill holes 15 mm
apart if possible. Reduced tilting angle of the mounting
bracket.
The drive can be mounted on the header (S) or on the ceiling (D).
Measure the front of the center of the door (VM) and mark on the door
and header or ceiling.
15
½
½
½
½
HMHM
15
VM
74mm 74mm
10mm
65mm
14
THP
Make a mark 74 mm to the right and left of the center of the door (VM)
and fasten at the same height on the header or ceiling (as per picture 9).
Drill two holes (Ø 10 x 65 mm deep).
NOTE!
Wear safety glasses while drilling.
Take into account the thickness of the ceiling, especially with
regard to prefab concrete garages!
Open the door. Project the mark from the center of the door to the
ceiling (HM).
Close the door.
NOTE!
Protect the controller housing against damage.
16
2
S10
4
5
31
S10
4
5
31
B
A/C
Insert anchor ttings (1). Lift the drive (2) at the front. Tightly fasten
header tting (3) at the front with two bolts (4) and U-washers (5).