Mount the controller housing and
connect
Selection of the installation variant
ATTENTION!
1. Control or regulating units in a xed position must be
mounted within sight of the door. They may not, however,
be mounted close to moving parts and must be at least
1.5 m above the ground.
NOTE!
Cables should always be permanently installed. Install cables
in such a manner that it is possible to extend the power
supply lines for variant A (e.g. install with a slack loop if the
cable is to be installed at a right angle to the C-rail).
ATTENTION!
Danger due to electric current!
Only touch the controller (4) on the outer edge.
Don't touch the electronic components.
22
1
2
4
3
Time
Reset
Radio
LED2
LED1
Time
Reset
Radio
LED2
LED1
Reset
Radio
LED2
LED1
Reset
Radio
LED2
LED1
Take off the lamp cover (1). Unscrew the screws (2) and take off the
cover (3), remove the controller (4).
Installation variant A/B
B23
1,6m
3
1
2
4
2
4
1,6m
3
1
A23
2
4
2
4
Choose a suitable location for the controller housing (1) close to an
existing wall socket (2). The minimum height above the ground is 1.6 m.
ATTENTION!
Bear in mind the installation position of the controller
housing (1). Ensure that the maximum length of the control
cable (3) of 6900 mm is not exceeded.
Install the control cable (3) (24 V) to the controller housing (1) in the
garage. Do not plug in the power mains plug (4) yet.
24
25
2
1
2
3
4
5
6
1
2
3
4
5
6
5
34
4
95
S6
1
2
5
6
ca 150
ATTENTION!
Do not drill into the power supply line to the wall socket!
Do not plug in the power mains plug yet.
Drill two holes (Ø 6 x 40 mm deep). Insert anchor ttings (2) into the
drill holes.
Afx the controller housing with two screws (1) and two washers (6),
align the unit properly and rmly tighten the screws.
Insert the end of the control cable (5) through the back of the controller
housing (4).
Connect the control cable (5): With hinged double doors, connect the
wire marked with 3 (green) to terminal 3 and the wire marked with 4 (red)
to terminal 4 of the direct connector (2). Shorten the control cable (5)
if necessary.
NOTE!
With hinged double doors, connect the wire marked with 3
(green) to terminal 4 and the wire marked with 4 (red) to termi-
nal 3 of the direct connector (2).
25