Operating Instructions and Installation Instructions
Functions and connections
t
– 25
Partial opening (DIP 8)
Depending on the setting, this function partially opens the door.
Use examples: airing out the garage, opening the side-sectional door for
personal access, and many others. The partial opening can be used with
two buttons or with hand-held transmitters.
2
1
ON
3
4
5
6
8
7
DIP switch 8
OFF Deactivated
ON Activated, DIP switch 7 non-functional
Partial opening with 2 buttons
Install additional button and connect to terminals 7 + 8 as button 2. Refer to
the chapter “Functions and connections - connecting button 2 (DIP 2)”.
• Button 1 always opens the door completely.
If the door is partially opened with button 2, pressing button 1 opens the
door completely.
• Button 2 opens the gate partially only if the gate is closed.
If the gate has been completely opened with button 1 or partially
opened with button 2, pressing button 2 again closes the gate.
Procedure
1. Close door.
2. DIP switch 8 ON activates partial opening.
⇒ Always leave DIP switch 8 set to ON, the OFF setting immediately
deletes the set partial opening.
3. Press button 2 (open door from CLOSED end position).
⇒ Door opens until button 2 is pressed again or the door reaches the
“door OPEN” end position.
4. Press button 2 once the desired position is reached.
5. Close door with button 2.
Partial opening saved and pressing button 2 opens the gate
to the saved position. Set DIP switch 8 to OFF to delete the
partial opening setting.
Partial opening with the hand-held remote control
(2-channel operation)
Programming the 2 buttons of the remote control, e.g. button 1 on radio
channel 1 and button 2 on radio channel 2.
• Radio channel 1 always has the same function as button 1.
• Radio channel 2 always has the same function as button 2.
Connecting external antenna
As-delivered status: unassigned
2
1
O
N
DIP
3
4
5
6
8
7
6
TorMinal interface
See TorMinal owner’s manual.
2
1
ON
3
4
5
6
7
5
6
Carriage circuit board
5
2
1
4
6
7
8
3
Terminal 1 Chain current draw
Terminal 2 Rail current draw
Terminal 3 + 4 Door OPEN end switch
Terminal 5 Motor cable
Terminal 6 Motor cable
Terminal 7 + 8 Door CLOSE end switch