Operating Instructions and Installation Instructions

– 7
t
Safety instructions
ATTENTION!
Important instructions for safe installation. Observe all
installation instructions – improper installation can lead to
serious injuries!
¾ The mains supply line that has been provided may not be shortened
or extended.
¾ The voltage of the power source must correspond with the voltage
listed on the drive type plate.
¾ All devices to be connected externally must have a safe isolation
of the contacts from the mains voltage supply, in accordance with
IEC 60364-4-41.
¾ Live parts of the drive (voltage-carrying parts, e.g. C-rail) may not be
connected to the ground or with live parts or grounding conductors of
other electrical circuits.
¾ Wiring for external devices must be installed in accordance with
IEC 60364-4-41.
CAUTION! RISK OF DEATH!
Remove all cords or straps necessary to operate the door
by hand.
Tools required
Mit SOMMER sind Sie immer gut ausger
ichtet!
Personal safety equipment
¾ Safety glasses (for drilling).
¾ Protective gloves (e.g. when handling cut-off pieces of perforated strip
steel).
Install slip door safeguard or
emergency release lock
There is a slip door installed in the door, but no slip door safeguard.
Install slip door safeguard (see accessories instructions).
There is no slip door in the door and no second entrance to the garage.
Install an emergency release lock or Bowden cable to enable
unlocking from outside (see accessories instructions).
Installation preparations