Operating Instructions and Installation Instructions
– 7
t
Safety instructions
ATTENTION!
Important instructions for safe installation. Observe all
installation instructions – improper installation can lead to
serious injuries!
¾ The mains supply line that has been provided may not be shortened
or extended.
¾ The voltage of the power source must correspond with the voltage
listed on the drive type plate.
¾ All devices to be connected externally must have a safe isolation
of the contacts from the mains voltage supply, in accordance with
IEC 60364-4-41.
¾ Live parts of the drive (voltage-carrying parts, e.g. C-rail) may not be
connected to the ground or with live parts or grounding conductors of
other electrical circuits.
¾ Wiring for external devices must be installed in accordance with
IEC 60364-4-41.
CAUTION! RISK OF DEATH!
Remove all cords or straps necessary to operate the door
by hand.
Tools required
Mit SOMMER sind Sie immer gut ausger
ichtet!
Personal safety equipment
¾ Safety glasses (for drilling).
¾ Protective gloves (e.g. when handling cut-off pieces of perforated strip
steel).
Install slip door safeguard or
emergency release lock
• There is a slip door installed in the door, but no slip door safeguard.
⇒ Install slip door safeguard (see accessories instructions).
• There is no slip door in the door and no second entrance to the garage.
⇒ Install an emergency release lock or Bowden cable to enable
unlocking from outside (see accessories instructions).
Installation preparations