Quick Start Guide

09.20.17
Connecting the Wire
The R10SUB ENC and R12SUB ENC feature a unique
terminal system. The binding posts are turned to allow
the wire to be run through both binding posts. This is
done to increase contact area and provide the most
secure and long lasting connection possible
(see Figure 1).
1. Loosen all four binding posts to allow the wire to be
pushed through.
2. Strip o approximately 1 1/4” (32mm) of jacket from
the wires.
3. Run the wire through the appropriate terminals.
4. Tighten the binding posts.
5. Tighten the provided zip tie around the wires
(see Figure 1).
Installing the Enclosure
1. Determine the proper location for the
subwoofer enclosure.
Box Contents R10SUB ENC
(1) Quickstart Guide
(1) R10SUB ENC with integral mounting rails
(compatible with Sonance R10SUB)
(1) Cover plate
(8) Flat Head Phillips screws for mounting
Box Contents R12SUB ENC
(1) Quickstart Guide
(1) R12SUB ENC with integral mounting rails
(compatible with Sonance R12SUB)
(1) Cover plate
(12) Flat Head Phillips screws for mounting
Figure 1: Binding Posts
Figure 2: Enclosure
Drywall and Screw Installation
To maximize performance and minimize noise and
vibration it is strongly recommended that one complete
piece of drywall is installed over the subwoofer location
(see Figure 3).
Drywall screws should be installed at a spacing of 8”-10”
(203mm-254mm). If drywall is installed on the wall surface
behind the subwoofer enclosure, drywall screws should
also be installed following these instructions.
IMPORTANT: DO NOT INSTALL DRYWALL SCREWS INTO THE
ENCLOSURE. THE ENCLOSURE IS DESIGNED TO FLOAT INSIDE
THE WALL.
Figure 3: Attached Enclosure
2. Determine the correct height to mount the enclosure.
Allow at least 1” (25mm) around the perimeter of the
cover plate for clearance of the grille frame and grille.
3. Verify the enclosure is level using a bubble level.
The grille has a limited range of adjustment, ensuring
the enclosure is level will greatly simplify the
completion of the installation (see Figure 2).
4. Attach the box to the stud or joist bay using the
supplied wood screws. Use 4 screws per side on the
R10SUB ENC and 6 screws per side on the R12SUB
ENC (see Figure 3).
5. Drywall should be installed up to the edges of the
cover plate. Do not leave more than an 1/8” (3mm)
gap around the perimeter of the cover plate.
©2017 Sonance. All rights reserved. Sonance is a registered trademark of Dana Innovations. Due to continuous product improvement, all features and specications are subject to change
without notice. For the latest Sonance product specication information visit our website: www.sonance.com
SONANCE • 991 Calle Amanecer • San Clemente, CA 92673 USA • Phone: (949) 492-7777 • FAX: (949) 361-5151 • Technical Support: (949) 492-7777
R10SUB ENC | R12SUB ENC QUICKSTART GUIDE
REFERENCE IN-WALL ENCLOSURE
33-7914

Summary of content (1 pages)