Quick Start Guide

Last Update: 1/4/21
Applications Manual for Sound Recording with iOS
© 2020 Sonic Presence, Inc. / All products US and International Patent Pending / sonicpresence.com
42
This table shows our test results for the Røde App. Note the Apps meter is not calibrated, so we indicate the playback level
by noting the lit LEDs: red, yellow and green.
Now you can see how the Apps meter readings correspond to the digital input signal level and the phone’s analog output.
We’re looking for linearity, meaning a 50% decrease in the generator mV signal level should correspond to a 6dB decrease
in the output level. You might notice some slight discrepancies at the top of the scale as the level approaches 0dB. That’s
the reason you want to keep your maximum recordings levels below -6dB or lower to avoid any distortion. Don’t worry
about noise as you would with analog recording. This is digital. The noise floor is more than 90dB below your recording
level. For practical purposes, we can say there is no noise!
Function
Generator
Sonic USB
Interface
analog
digital
analog
Voltmeter
calibrated
1Volt rms =0dB
iPhone
Android
App
Røde
scale green green green green yellow red red
scale marking na na na na na na na
generator mV rms 5 10 13 20 50 80 160
calculated level in dB -30.1 -24.1 -21.8 -18.1 -10.1 -6.0 0
PB level (analog) -32 -24 -18 na -12 -8 -4
reference acoustic level 94dB SPL 114dB SPL