SignalLED User Handbook
SIGN ALLED STUDIO ILLUM INATED SIGN S H A N D BOOK S I G N A LLE D S T UDI O I LLUM I NAT ED S I G N S H A N DB OO K b This handbook is for use with all SignalLED signs which use the LD-RPC remote control for programming ©Sonifex Ltd, 2009 - 2011 All Rights Reserved Revision 2.04, October 2011 Sonifex Ltd, 61, Station Road, Irthlingborough, Northants, NN9 5QE, England. Tel: +44 (0)1933 650 700 Fax: +44 (0)1933 650 726 Email: sales@sonifex.co.uk Website: http://www.sonifex.co.
CONTENTS Warranty Information 1 Introduction 1 Safety Information Handling Notes 1 1 2 Installation 4 Mounting The Sign Opening The End Covers LD-20F1 & LD-40F1 Flush Sign Mounting Requirements End Mounting Requirements LD-KC1 Ceiling Mounting Kit Connecting The Power and Signal Connections For Flush Mounted Signs Connecting The Power & Signal Connections For End Mounted Signs Power Supply 4 4 4 5 5 6 7 7 Programming Colour & Illumination Modes 9 Setting The Colour & Display Mode(s) of The Sig
FIGURES FI G U RE S Figures ii Fig 1-1: Australia Certificate of Approval 2 Fig 1-2: CB Certificate of Approval 2 Fig 1-3: CE Certificate of Approval 3 Fig 1-4: UL Certificate of Approval 3 Fig 2-1: LD-20F1 & LD-40F1 Flush Sign Mounting Requirements 4 Fig 2-2: End Mounting Requirements 5 Fig 2-3: LD-KC1 Ceiling Mounting Kit 5 Fig 2-4: Cable Routing Cut-Outs 6 Fig 2-5: Opening The Access Door 6 Fig 2-6: Mode Settings & Connection Bloc 6 Fig 2-7: LD-IT End Mount Sign Installation Tool
WARR ANT Y & INTRODUC TION 1 Warranty Information This product is supplied with a 12 month back to base warranty. For further details, please refer to the Sonifex website: http://www.sonifex.co.uk/company/terms/index.shtml In order to register the date of purchase so that we can keep you informed of any design improvements or modifications, it is important to complete the warranty registration document that is enclosed and return it to Sonifex Ltd in the UK.
1 POWE R S U P PLY APPROVAL DOCUMENTS Power Supply Approval Documents POWER SUPPLY APPROVAL DOCUMENTS The power supply used with the SignalLEDs is UL, EC and CC approved. For a more detailed view of the certificates, please check online at: http://www.sonifex.co.uk/ signalled/index.
P OWER SUP P LY APPROVAL DOCUMENTS POWER SUPPLY APPROVAL DOCUMENTS Fig 1-3: CE Certificate of Approval 1 Fig 1-4: UL Certificate of Approval SignalLED User Handbook 3
2 INS TA LL AT IO N Installation Mounting The Sign Route the signal and power supply cables before finalising the mounting of the sign. These cables can be routed either through the aperture, or through the cable cut-outs in the back of the wall mount moulding. INS TA LL AT I ON The LED sign should be mounted on a firm solid surface.
IN STALL ATION 2 End Mounting Requirements Ceiling 38mm minimum = Wall Mounting Plate shown in red = Wall Mounting Holes = Hanger Slots 44mm I N S TA LL AT I ON To create an attractive invisible-fixing finish, the SignalLED assembly is clipped into a wall mount plate. The wall mount plate must be securely fitted to a smooth, solid surface before 81mm minimum attempting to fit the SignalLED assembly.
2 INS TA LL AT IO N Connecting The Power and Signal Connections For Flush Mounted Signs To get access to the cable connection block and the mode switches which are on the PCB inside the sign, the door on the underside of the end plastic moulding must be opened. To open the door push the clip towards the sign and pull down on the small lip, see Fig 2-5. Do not attempt to remove the door from the end moulding. Access to the connection block and the mode switches is possible with the door fully open.
IN STALL ATION 2 Connecting The Power & Signal Connections For End Mounted Signs It is recommended that the LD-IT SignalLED end mount sign installation tool is used to assist the termination of the power and signal connections. The tool is designed to hold the sign on the pre-fitted wall mount plate leaving both hands free to make the connections, as shown in Fig. 2-7.
2 INS TA LL AT IO N sign and are pulled low (to 0V, pin 3) to activate on signs manufactured before 14/10/2011. If driving more than one LED sign from the signalling inputs, or power supply, then the LED sign pins should be diode protected to prevent a reverse current condition.
PROGR AMMING 3 Programming Colour & Illumination Modes SignalLED signs bought after 1st December 2010 are programmed using a separate handheld remote control, instead of being programmed using DIPSwitches on the sign. Please note that the remote control must be ordered separately, LD-RPC. Please contact your Sonifex distributor for ordering information.
3 PROGR AMMING %VSJOH QSPHSBNNJOH UIF JOQVU TUBUF CFJOH QSPHSBNNFE JT SFøFDUFE JO UIF -&%T positioned in the opening: PROGR AMMING Fig 3-1: IR Opening & Input LEDs Input State Input 1 Input 2 Red LED (Input 1) Green LED (Input 2) 1 Unconnected Unconnected Off Off 2 Connected to 0V Unconnected On Off 3 Unconnected Connected to 0V Off On 4 Connected to 0V Connected to 0V On On Fig 3-2: Input States Once in programming mode the sign will default to input state 1, QSFTT UIF */16
PROGR AMMING 3 Pressing the + (2) button advances the Section 1 divide position one LED for each time you press the button. If Section 1 reaches Section 2 then Section 2 is pushed back (i.e. its divide position retreats). The divide point for Section 1 or Section 2 cannot be moved so that the Section 1 is not visible.
3 PROGR AMMING Setting The Illumination Mode PROGR AMMING 5P TFU UIF *MMVNJOBUJPO .PEF QSFTT UIF .
T E C HNI C AL SP ECIFIC ATION 4 Technical Specifications Physical Specification Power Supply: 333mm x 129mm x 60mm 527mm x 129mm x 60mm 527mm x 129mm x 60mm Equipment Type Single Flush Mounting Signs (20cm): LD-20F1REC 20cm ‘RECORD’ Sign LD-20F1ONA 20cm ‘ON AIR’ Sign LD-20F1MCL 20cm ‘MIC LIVE’ Sign Single Flush Mounting Signs (40cm): LD-40F1REC 40cm ‘RECORD’ Sign LD-40F1ONA 40cm ‘ON AIR’ Sign LD-40F1MCL 40cm ‘MIC LIVE’ Sign LD-40F1PHN 40cm ‘PHONE’ Sign LD-40F1TRF 40cm ‘TRAFFIC FLAG ON’ Sign LD-40F1ADB
5 APPENDICES Appendix 1 LD-KE1 SignalLED Conversion Kit, Single Flush Mount to End Mount 5P DPOWFSU UIF -% ' -% ' TUZMF øVTI NPVOU TJOHMF TJEFE TJHOT JOUP TJOHMF TJEFE FOE mount signs you will need to fit the LD-KE1 conversion kit. Please follow these instructions carefully. A P P E N D I CE S Note: You’ll need the following tools to use the conversion kit:, a No. 0 and No.1 Pozi-drive screwdriver. Take care not to damage the clear surface of the sign board.
AP P END ICES 5 3) Align the 4 pins of the extrusion end cover with the screw holes in the exposed end of the aluminium tube. Note the orientation of the cut-out with the clear sign board and press fit the end cover fully onto the aluminium tube. 0QFO UIF FOE DPWFS PO UIF SJHIU IBOE øVTI NPVOU BTTFNCMZ CZ SFNPWJOH UIF TFMG tapping screw with a No.1 pozi-drive screwdriver. 3FNPWF UIF øVTI XBMM NPVOU NPVMEJOH GSPN UIF FOE NPVMEJOH CZ VOTDSFXJOH UIF screws visible under the cover See Fig 5-4.
A P P E N D I CE S 5 APPENDICES Fig 5-4: Removing the Right Hand Flush Wall Moulding Fig 5-5: Right Hand Conversion Re-Assembly Left Hand Side Fitting of the Conversion Kit Note: With this conversion you will be removing the PCB from the sign so full anti-static precautions must be taken to protect the PCB from damage. Failure to do so may result in the sign not working and invalidating the warranty.
AP P END ICES 5 5IJT DPNCJOBUJPO JT UIFO öYFE UP UIF MFGU IBOE øVTI NPVOU BTTFNCMZ FOE NPVMEJOH with the 4 supplied No.4 x ¾ self tap screws. Do not substitute any other screws in these positions and do not reuse the screws removed from these positions because they will not support the sign correctly. 10) Please refer to the installation notes for the LD-40E style signs to complete the final fitting and colour/configuration set-up.
5 APPENDICES Appendix 2 SignalLED Preconfigurations Please note that your SignalLED sign has been preconfigured for the following operation, depending on the sign chosen.
AP P END ICES 5 SignalLED Preconfigurations (continued...
w w w. s o n i fe x . c o. u k t:+44 (0)1933 650 700 f:+44 (0)1933 650 726 s a l e s @ s o n i fe x . co.