Handbook

Table Of Contents
Condence Monitors User Handbook
CONFIDENCE MONITORS
INTRODUCTION
3
CONFIDENCE MONITORS INTRODUCTION
1
RM-CA2 Confidence Monitor, 2 LED Meters &
2 Analogue Stereo Inputs
Fig 1-1: RM-CA2 Condence Monitor Front Panel
The RM-CA2 is a 1U rack-mount unit oering quality loudspeaker monitoring and 2 channel
metering of two stereo analogue audio sources. Input 1 has stereo balanced Neutrik™
XLRs and Input 2 has both stereo balanced Neutrik™ XLRs and stereo unbalanced RCA
phono connectors, these inputs are mixed together in the analogue domain. The balanced
analogue inputs can be wired unbalanced if required.
Sources are selected via a front panel push-button button, with clear LED indication of the
current source.
A rear panel DIP switch setting allows the unit to monitor either:
Stereo signals, with the two front panel control knobs acting as stereo volume and
balance control, to alter the stereo imaging of the left and right channels, or
Dual mono signals, with the two front panel control knobs acting as left and right
volume controls.
There is a front panel headphone socket which responds to the volume controls and the
headphone socket automatically mutes the internal loudspeakers when a plug is inserted.
A pair of line-level analogue audio outputs follow the selected source at the selected level,
or optionally at 10dB lower (if using the unbalanced input), set via rear-panel DIP switch 5.
The level of the chosen source is shown on an 8 segment LED bar-graph display with PPM
and VU scales indicated. The bar-graph can optionally be lowered by 10dB (if using input 2),
set via rear-panel DIP switch 1.
A single phase error LED indicates phase error conditions.
The three-way loudspeaker system is fed via a DSP-based active crossover and a trio of
highly ecient Class-D ampliers. Careful attention to driver selection, materials and
case design, plus active DSP equalisation, has ensured a at response and outstanding
reproduction from such a shallow unit. A protective limiter prevents damage to the
loudspeakers under overload conditions
The RM-CA2 operates from global mains voltages (85-264V AC, 47-63Hz) without
adjustment.