Handbook
Table Of Contents
- Warranty
- Safety Information
- Installation Information
- Confidence Monitors Introduction
- RM-CA2 Confidence Monitor, 2 LED Meters &
- 2 Analogue Stereo Inputs
- RM-CAD8 Confidence Monitor, 2 LED Meters, 2 Analogue &
- 6 Digital Stereo Inputs
- Technical Specification RM-CA2 & RM-CAD8
- Fig A: Packing List
- Fig B: Power Connections
- Fig C: Mains Lead Table
- Fig 1-1: RM-CA2 Confidence Monitor Front Panel
- 
- Fig 1-3: Confidence Monitor Block Diagram
- Fig 1-4: RM-CA2 Front Panel Controls
- Fig 1-5: RM-CAD8 Front Panel Controls
- Fig 1-6: RM-CA2 Source Selector Button Fig 1-7: RM-CAD8 Source Selector Button
- Fig 1-8: RM-CA2 & RM-CAD8 Meters & Phase Error LED
- Fig 1-11: RM-CA2 & RM-CAD8 Meters & Phase Error LED
- Fig 1-12: Confidence Monitor RM-CA2 Rear
- Fig 1-13: Confidence Monitor RM-CAD8 Rear
- Fig 1-14: DIPSwitch Settings
10
Condence Monitors User Handbook
REAR PANEL CONNECTIONS
& OPERATIONS
3
REAR PANEL CONNECTIONS & OPERATIONS
DIPSwitch Settings
Fig 1-14: DIPSwitch Settings
Reduce Meter Levels by 10dB - DIPSwitch 1
This DIPSwitch is only valid when analogue input 2 is selected and when the switch is on it
will reduce the meter levels by 10dB. This switch will mainly be used when the unbalanced
inputs are used. In this case a 10dB gain is applied to the signal levels P650 that the
inputs from domestic equipment will be increased to levels typically used for professional
(unbalanced) equipment. If you wish to monitor the actual level of the unbalanced
incoming signals then this switch needs to be on. On the other hand if the balanced
input 2 is being used then the switch should be o.
Level/Balance Control Selection - DIPSwitch 3
This DIPSwitch switches the level and balance controls between independent left and right
level (switch o) and stereo level and balance control (switch on).
Reduce Output Levels by 10dB - DIPSwitch 5
If the audio output is connected to unbalanced consumer equipment then this switch
should be used to reduce the output levels by 10dB.
Meter Characteristic Selection - DIPSwitch 7
This DIPSwitch changes the metering characteristics between VU (o ) and PPM (on).