In back-up mode, the back-up source must provide enough power for RTC
operation. Refer to the table for the amount of current required.
The following table shows voltage characteristics for both modes.
If the voltage drops below 1.0 V in back-up mode, the RTC will stop
working. The following diagram shows the RTC connections.
Figure 5.13 RTC connections
Parameter Min. Typ. Max. Units
Supply Voltage RTC (normal mode -
charging the capacitor)
1.6 1.8 2.0 V
Supply Voltage RTC (back-up mode -
Capacitor provides the current)
1.0 1.8 2.0 V
Current drawn 5.0 10.0 µA
Backup
supply
VRTC
+
GR47
DGND