9-3 Operation Warnings
Operation/error messages
An operation or error message is displayed in the
operation/error message display area in the viewfinder.
1) To replace the backup battery, contact your nearest Sony dealer.
Notes on CCD image sensors
Vertical smear
Smear tends to be produced when an extremely bright
object is being shot; it is more likely to occur with a faster
electronic shutter speed.
Vertical smear
Aliasing
When patterns of stripes or lines are shot, they may appear
jagged.
Operation/error
message
Meaning
AUTO INTERVAL
**M**S
Indicates the camera is in the Auto
Interval Rec mode. **M**S
indicates the shooting interval.
MANU INTERVAL
*FRAME
Indicates the camera is in the
single shot mode of the Manual
Interval Rec mode. *FRAME
indicates the number of frames.
INTERVAL **S(M/
H)*FRAME
Indicates the camera is in the
consecutive mode of the Manual
Interval Rec mode. **S(M/H)
indicates the trigger interval and
*FRAME indicates the number of
frames.
LOW LIGHT Appears, depending on the setting,
to indicate the subject illumination
is inadequate.
REC INH. Appears when attempting to record
on a write-protected disc.
Humid Disturbed INT
REC
Appears when there are portions
where recording has failed due to
condensation while shooting
pictures at intervals (using the
interval rec function).
ON-BOARD BATTERY
EMPTY
Appears when the backup battery
for the internal clock has been used
up.
1)
Vertical tails show on the
image.
Bright object (mercury lamp,
the sun, reflections, etc.)
Monitor screen