Camcorder User Manual
Table Of Contents
- Table of Contents
- Chapter 1 Overview
- Chapter 2 Locations and Functions of Parts and Controls
- Chapter 3 Recording and Playback
- Chapter 4 Thumbnail Search
- Chapter 5 Adjustments and Settings for Recording
- Chapter 6 Menu Displays and Detailed Settings
- 6-1 Menu Organization and Operation
- 6-2 Status Display on the Viewfinder Screen
- 6-2-1 Layout of the Status Display on the Viewfinder Screen
- 6-2-2 Selecting the Display Items
- 6-2-3 Display Modes and Setting Change Confirmation/ Adjustment Progress Messages
- 6-2-4 Setting the Marker Display
- 6-2-5 Setting the Viewfinder
- 6-2-6 Recording Shot Data Superimposed on the Color Bars
- 6-2-7 Setting the Shot ID
- 6-2-8 Displaying the Status Confirmation Windows
- 6-2-9 Confirming the Image of the Return Video Signal in the Viewfinder
- 6-3 Adjustments and Settings from Menus
- 6-3-1 Setting Gain Values for the GAIN Selector Positions
- 6-3-2 Selecting the Output Signals
- 6-3-3 Setting the Color Temperature Manually
- 6-3-4 Specifying an Offset for the Auto White Balance Setting
- 6-3-5 Assigning Functions to ASSIGN 1/2/3/4 Switches
- 6-3-6 Setting the Date/Time of the Internal Clock
- 6-3-7 Selecting the Lens File
- 6-3-8 Selecting the Aspect Ratio
- 6-3-9 Setting the CCD Scan Mode
- 6-4 Resetting USER Menu Settings to the Standard Settings
- Chapter 7 Saving and Loading User Setting Data
- Chapter 8 Setting Up the Camcorder
- Chapter 9 Maintenance
- Appendixes
- Index
Appendixes
147
Menu List
04 GAMMA GAMMA OFF/ON ON Turns the gamma correction function on or
off.
STEP GAMMA 0.35 to 0.90 0.45 Sets the master gamma correction curve in
steps.
MASTER GAMMA
(–99 to +99)
0 Sets the master gamma correction curve.
R GAMMA
(–99 to +99)
0 Sets the R gamma correction curve.
G GAMMA
(–99 to +99)
0 Sets the G gamma correction curve.
B GAMMA
(–99 to +99)
0 Sets the B gamma correction curve.
TEST OUT SELECT ENC/R/G/B ENC Selects the output signal of TEST OUT
connector.
GAMMA SELECT STD/FILM STD Selects the gamma table.
GAMMA SEL (STD/
FILM)
1 to 6 (STD)
1 to 5 (FILM)
3/1 Selects the gamma table of STD/FILM.
05 BLK GAMMA BLACK GAMMA OFF/ON OFF Turns the black gamma correction on or off.
BLK GAMMA RANGE LOW/L.MID/
H.MID/HIGH
HIGH Sets the range affected by black gamma.
MASTER BLK
GAMMA
(–99 to +99)
0 Adjusts the master black gamma.
R BLACK GAMMA
(–99 to +99)
0 Sets the correction curve of the R black
gamma.
G BLACK GAMMA
(–99 to +99)
0 Sets the correction curve of the G black
gamma.
B BLACK GAMMA
(–99 to +99)
0 Sets the correction curve of the B black
gamma.
TEST OUT SELECT ENC/R/G/B ENC Selects the output signal of TEST OUT
connector.
06 KNEE KNEE OFF/ON ON Turns the knee correction circuit on or off.
KNEE POINT 50 to 109 85.0 Sets the knee point level.
KNEE SLOPE
(–99 to +99)
0 Set the knee slope level.
KNEE SATURATION OFF/ON ON Turns the knee saturation function on or off.
KNEE SAT LEVEL
(–99 to +99)
0 Sets the knee saturation level.
WHITE CLIP OFF/ON ON Turns the white clipping function on or off.
WHITE CLIP LEVEL 100.0 to 109.5% 109.0/
105.0
Adjusts the white clipping level.
07 DETAIL 1 DETAIL OFF/ON ON Sets the detail correction function on or off.
APERTURE OFF/ON ON Turns the aperture correction function on or
off.
DETAIL LEVEL
(–99 to +99)
0 Sets the general level of the detail signal.
APERTURE LVL
(–99 to +99)
0 Sets the aperture level.
DTL H/V RATIO
(–99 to +99)
0 Sets the level of the V detail signal.
CRISPENING
(–99 to +99)
0 Sets the crispening level.
LEVEL DEPEND OFF/ON ON Turns the level depend function on or off.
LV. DEPEND LVL
(–99 to +99)
0 Sets the level of the level depend.
DETAIL FREQ.
(–99 to +99)
0 Sets the frequency of the H detail signal.
No. Page Item Settings Default Description