User's Manual

13
FWD-40LX2F/40LX2X/32LX2F/32LX2X
KLH-W32/W26
Answer Header Answer Check Sum
Control 0x70 0x00 0x70 Completed
0x70 0x03 0x73 Command Canceled
Answer Header Answer Return to Data Size Return Data1 Return Data2 Check Sum
Enquiry 0x70 0x00 0x03 Code Table (2-c) Code Table (2-b)[b] 0xXX Completed
Code Table (2-b)
[a]Function [b]Range/Switch code Command
Control Enquiry Standby Power On
0x05 Red Gain 0x00-0xFF Yes Yes Disable Enable
0x06 Green Gain 0x00-0xFF
0x07 Blue Gain 0x00-0xFF
Code Table (2-c)
Format Select
0x00 Cool
0x01 Neutral
0x02 Warm
6. Size/Shift
(a) 8Bits Register
Syntax Header Category Function Data1 Data2 Check Sum
Control 0x8C 0x20 Code Table (3-b)[a] 0x02 Code Table (3-b)[b] 0xXX
Enquiry 0x83 0xFF 0xFF 0xXX
Answer Header Answer Check Sum
Control 0x70 0x00 0x70 Completed
0x70 0x01 0x71 Limit Over
0x70 0x02 0x72 Limit Under
0x70 0x03 0x73 Command Canceled
Answer Header Answer Return to Data Size Return Data1 Check Sum
Enquiry 0x70 0x00 0x02 Code Table (3-b)[b] 0xXX Completed