User's Manual

13
For details, see “Setting the maximum RF output power
(MAX RF POWER)” (page 13).
Setting the maximum RF output
power
(MAX RF POWER)
You can set the maximum RF output power of the unit.
2mW MAX: Sets the maximum to 2 mW.
10mW MAX: Sets the maximum to 10 mW.
25mW MAX
: Sets the maximum to 25 mW.
The setting for this function cannot be changed during
actual signal transmission. To change the setting, turn
off the transmitter first. Then, while holding down the
SET button, turn the power on. And then, change the
setting after the signal transmission has stopped.
To start signal transmission with the selected RF output
power setting, turn off the power and then turn it on
again.
Always perform pairing after changing the maximum
RF output power setting for a transmitter. If you fail to
do so, configuration of RF output power settings via the
wireless remote control function may become
impossible.
For details on pairing, see “Using Cross Remote”
(page 7).
Displaying the accumulated use time
(TIME)
You can display the accumulated battery use time as a
rough estimate of total transmitter usage.
The factory setting is “00:00”.
To reset the accumulated time indication
1
Hold down the SET button until the time indication
flashes.
2
Press the – button so “00:00 RESET” appears, and
then press the SET button.
Using wireless remote control, this function can be
controlled from the receiver and other devices.
For details on wireless remote control function, see
“Using Cross Remote” (page 7).
Setting the brightness of the display
(BRIGHTNESS)
Ten levels of brightness can be selected for the organic
light-emitting diode display.
The selectable settings are the following:
(Dark) 1 2 3 4 5 6 7
8 9 10 (Bright)
Automatic dimming of the display
(DIMMER MODE)
The organic light-emitting diode display can be set to dim
or turn off after a certain amount of time.
AUTO OFF
: The display turns off after 30 seconds. The
display goes on again when you press the SET, +, or –
button.
AUTO DIMMER: The display dims after 30 seconds. The
display becomes bright again when you press the SET, +,
or – button.
ALWAYS ON: The display stays on at the brightness
level set with the BRIGHTNESS function.
Settings storage function (USER
MEMORY)
Store setting values on the unit, or load previously saved
setting values.
When you execute SAVE, the values for the following
settings will be saved.
NAME (transmitter name) setting
BAND (frequency band) selection
GP/CH (group/channel) selection
AF ATT (audio attenuator level) setting
LCF (low-cut filter) setting
LOCK function
RF REMOTE (wireless remote control) function
CODEC MODE (audio codec mode) setting
ENCRYPTION (encrypted transmission function)
setting
INPUT LEVEL (audio input level) setting
AF PHASE (audio phase switch) setting
RF POWER (RF transmission power) setting
MAX RF POWER (maximum RF transmission power)
setting
BRIGHTNESS (display brightness) setting
DIMMER MODE (automatic display dimmer) setting
POWER PRIORITY (power source priority) setting
When you execute LOAD, the saved setting values will be
loaded.
This function cannot be executed during actual signal
transmission. Turn the unit off, and then hold down the
POWER button while pressing the SET button to turn
the unit on in a state where signals are not transmitted
before execution.
To start signal transmission after using this function,
turn off the unit and then turn it on again.
You cannot execute LOAD if you have never executed
SAVE.
If you execute LOAD while performing the following
operations after setting values were stored, proper
communication with the receiver will not be possible. In
such cases, perform pairing or encrypted transmission
settings again.
Notes
Notes