Security Camera User Manual

56
Command List
Digital Zoom Combine mode
X12-NTSC/PAL
Digital Zoom Digital Zoom
Ratio Position Data
×1 4000
×2 6000
×3 6A80
×4 7000
×5 7300
×6 7540
×7 76C0
×8 7800
×9 78C0
×10 7980
×11 7A00
×12 7AC0
Digital Zoom Separate mode
Lens control
Zoom Position
0000 to 4000 to 7AC0
Wide end Optical Digital
Tele end Tele end
Focus Position
1000 to C000
Far end Near end
1000: Over Inf
2000: 20 m
3000: 10 m
4000: 5 m As the distance on the left
Focus Near
5000: 3 m will differ due to temperature
Limit
6000: 2 m characteristics, etc., use as
7000: 1.5 m approximate values.
8000: 32 cm * The lower 1 byte is fixed at
9000: 9.5 cm 00.
A000: 4.5 cm
B000: 2 cm
C000: 1 cm
Temperature Reading Conversion Value
(Reference Value)
Line number 00 to 0A
H-position 00 to 17
Blink
00: Dose not blink
01: Blinks
00 White
01 Yellow
02 Violet
Color 03 Red
04 Cyan
05 Green
06 Blue
00 01 02 03 04 05 06 07
AB CDE F G H
08 09 0a 0b 0c 0d 0e 0f
IJKLMNOP
10 11 12 13 14 15 16 17
QR STUVWX
18 19 1a 1b 1c 1d 1e 1f
YZ & ? ! 1 2
20 21 22 23 24 25 26 27
34 5678 9 0
28 29 2a 2b 2c 2d 2e 2f
ÀÈ ÌÒÙÁ É Í
30 31 32 33 34 35 36 37
ÓÚ ÂÊÔÆŒÃ
38 39 3a 3b 3c 3d 3e 3f
ÕÑ Ç ßÄ Ï Ö Ü
40 41 42 43 44 45 46 47
Å$
F
¥D ¿ ¡
48 49 4a 4b 4c 4d 4e 4f
ø“ : . , / -
Title setting
X12-NTSC/PAL
Digital Zoom Digital Zoom
Ratio Position Data
×100
×280
×3AA
×4C0
×5CC
×6D5
×7DB
×8E0
×9E3
×10 E6
×11 E8
×12 EB
Reading Value Temperature
pq (hex) Conversion
Value (ºC)
00 –3 to 3
0A 7 to 13
14 17 to 23
1E 27 to 33
28 37 to 43
32 47 to 53
3C 57 to 63