FLAT WIDE DISPLAY FWD-50PX2 PROTOCOL MANUAL 1st Edition
Table of Contents 1. Communication Parameter ................................................................ 1 2. Pin Configuration ..................................................................................... 1 3. Communication Data Format ........................................................... 1 4. General Function ..................................................................................... 3 5. Picture/Sound ...........................................................................
1. Communication Parameter 3. Communication Data Format (a) Control (Host → Request of Write to Display) Communication system RS-232C Synchronous system Asynchronous communication No. Item Value Baud rate 9600 bps 1 Header 0x8C:Control Character length 8 bit 2 Category 0xXX Parity None 3 Function 0xXX Start bit 1 bit 4 Data1 (Length) 0xXX Stop bit 1 bit 5 Data2 (Data1) 0xXX Flow control None : : 0xXX : : 0xXX X DataX 0xXX X+1 Check Sum 0xXX 2.
(c) Answer (Display → Response to Host) 1 Control answer 4 Error answer No. Item Value No. Item Value 1 Header 0xE0: Answer 1 Header 0x70: Answer 2 Answer* 0x00: No Function Error 2 Answer* 0x00: Completed 0x01: Check Sum Error 0x01: Limit Over 0x02: Data Length Error 0x02: Limit Under 0x03: Command Canceled 3 Check Sum 0xXX * 0x00: Completed 0x01: Limit Over Normal response. The packets was received normally, but the data value was over the upper limit.
4.
Code Table(1-a) [a]Function 0x06 0x0B 0x0C 0x0D 0x0E 0x0F Color System Picture Inversion Picture Orbit Orbit Range Orbit Cycle Language [b]Range/Switch Code 0x00 Auto 0x01 NTSC 0x02 NTSC4.
Code Table(1-a) [a]Function 0x41 0x49 0x65 BackGroud Auto Dimmer IP Setting Mode [b]Range/Switch Code 0x00 Gray 0x01 Dark Gray 0x02 Black 0x00 OFF 0x01 ON 0x00 DHCP 0x01 Manual Command Control Enquiry Standby Power On Yes Yes Disable Enable Yes Yes Disable Enable Yes Yes Enable Enable No Yes Enable Enable Yes No Enable Enable Yes Yes Enable Enable No Yes Disable Enable 0X02 Speed 0x66 0x67 0x68 0x24 IP Setting Execute IP Setting Result Speed Setting
Code Table(1-a) [a]Function 0x25 Input Detect (Option2) [b]Range/Switch Code 0x00 U3 (HD15) 0x01 U1 (CVBS/Y, C) 0x02 U2 (BNC) 0x03 Reserved 0x04 FW31/FW32 0x05 FW50 0x06 Reserved 0x07 Reserved 0x08 Reserved 0x09 Reserved Command Control Enquiry Standby Power On No Yes Disable Enable Yes Yes Disable Enable Yes Yes Disable Enable Yes Yes Disable Enable Yes Yes Disable Enable Yes Yes Disable Enable 0x0A Reserved 0x0B Reserved 0x0C Reserved 0x0D Reserved 0x0E Re
Code Table(1-a) [a]Function 0x35 [b]Range/Switch Code PAP Input Detect*2 (Left/Main) 0x0A INPUT2 RGB Command Control Enquiry Standby Power On No Yes Disable Enable No Yes Disable Enable 0x0B INPUT2 COMPONENT 0x0C OPTION1 VIDEO 0x0D OPTION1 S VIDEO 0x0E OPTION1 RGB 0x0F OPTION1 COMPONENT 0x36 PAP Input Detect*2 (Right/Sub) 0x10 OPTION2 VIDEO 0x11 OPTION2 S VIDEO 0x12 OPTION2 RGB 0x13 OPTION2 COMPONENT 0x20 INPUT1 DVI 0x0A INPUT2 RGB 0x0B INPUT2 COMPONENT 0x0C OPTION1 VIDEO 0x0D O
Code Table(1-a) [a]Function 0x42 IP Address 0x45 Control Mode [b]Range/Switch code 0x00 Main+Remocon Command Control Enquiry Standby Power On Yes Yes Enable Enable Yes Yes Disable Enable Yes Yes Enable Enable Yes Yes Enable Enable Yes Yes Enable Enable 0x01 Main 0x02 Remocon 0x03 Both Disable 0x46 On Off Timer Mode 0x47 On Timer Enable 0x00 Every Day 0x01 Day Of Week 0x48 Off Timer Enable bit0 Sunday 1: Enable, 0: Disable bit1 Monday 1: Enable, 0: Disable bit2 Tuesd
DNS Primary Syntax Header Category Function Data1 Data2 Data3 Data4 Data5 Check Sum Control 0x8C 0x00 0x63 0x05 Address 0 0x00-0xFF Address 1 0x00-0xFF Address 2 0x00-0xFF Address 3 0x00-0xFF 0xXX DNS Secondary Syntax Header Category Function Data1 Data2 Data3 Data4 Data5 Check Sum Control 0x8C 0x00 0x64 0x05 Address 0 0x00-0xFF Address 1 0x00-0xFF Address 2 0x00-0xFF Address 3 0x00-0xFF 0xXX Answer Header Answer Check Sum Control 0x70 0x00 0x70 Completed 0x7
Code Table(1-b) [a]Function 0x1D [b]Range/Switch code Color Matrix 0x00 YCbCr 0x01 YPbPr Command Control Enquiry Standby Power On Yes Yes Disable Enable Code Table(1-c) Format Select 0x00 480p 0x01 1080i 0x02 720p 0x03 480i Code Table(1-d) Input Select 0x00 Input2 0x01 Option1 0x02 Option2 (c) Time Control Clock Set (Hour, Minute) Syntax Header Category Function Data1 Data2 Data3 Check Sum Control 0x8C 0x00 0x22 0x03 Hour: 0x00-0x17 Minute: 0x00-0x3B 0xXX Syntax
Clock Set (Week) Syntax Header Category Function Data1 Data2 Check Sum Control 0x8C 0x00 0x23 0x02 Week: Code Table(1-e) 0xXX Syntax Header Category Function Data1 Data2 Check Sum Enquiry 0x83 0x00 0x23 0xFF 0xFF 0xA4 Answer Header Answer Check Sum Control 0x70 0x00 0x70 Completed 0x70 0x01 0x71 Limit Over 0x70 0x02 0x72 Limit Under 0x70 0x03 0x73 Command Canceled Answer Header Answer Return to Data Size Return Data1 Check Sum Enquiry 0x70 0x00 0x02
Code Table(1-f) [a]Function [b]Range/Switch code Command Control Enquiry Standby Power On Yes Yes Disable Enable Yes Yes Disable Enable Yes Yes Disable Enable Yes Yes Disable Enable Picture Inversion 0x20 Invert Start Time 0x21 Invert End Time Clock Set 0x22 Hour, Minute 0x23 Week On Timer 0x50 Sunday 0x51 Monday 0x52 Tuesday 0x53 Wednesday 0x54 Thursday 0x55 Friday 0x56 Saturday 0x57 Every day Off Timer 0x58 Sunday 0x59 Monday 0x5A Tuesday 0x5B Wednesday
Code Table(2-a) [a]Function [b]Range/Switch code Command Control Enquiry Standby Power On 0x00 Contrast 0x00-0x64 Yes Yes Disable Enable 0x01 Brightness 0x00-0x64 Yes Yes Disable Enable 0x02 Chroma 0x00-0x32 Yes Yes Disable Enable 0x03 Phase 0x00-0x64 Yes Yes Disable Enable 0x04 Color Temp 0x00 Cool Yes Yes Disable Enable 0x01 Natural 0x02 Warm 0x03 Color1 0x04 Color2 0x05 Color3 Yes Yes Disable Enable Yes Yes Disable Enable Yes Yes Disable Enabl
(b) Color Temp Syntax Header Category Function Data1 Data2 Data3 Check Sum Control 0x8C 0x10 Code Table(2-b)[a] 0x03 Code Table(2-c) Code Table(2-b)[b] 0xXX Syntax Header Category Function Data1 Data2 Check Sum Enquiry 0x83 0x10 Code Table(2-b)[a] Code Table(2-c) 0xFF 0xXX Answer Header Answer Check Sum Control 0x70 0x00 0x70 Completed 0x70 0x03 0x73 Command Canceled Answer Header Answer Return to Data Size Return Data1 Return Data2 Check Sum Enquiry 0x70
Answer Header Answer Return to Data Size Return Data1 Check Sum Enquiry 0x70 0x00 0x02 Code Table(3-b)[b] 0xXX Completed Code Table(3-b) [a]Function [b]Range/Switch code Command Control Enquiry Standby Power On 0x00 H Size 0x00-0x3C Yes Yes Disable Enable 0x01 H Shift 0x00-0x3C Yes Yes Disable Enable 0x02 V Size 0x00-0x3C Yes Yes Disable Enable 0x03 V Shift 0x00-0x3C Yes Yes Disable Enable 0x04 Aspect Yes Yes Disable Enable Yes Yes Disable Enable Yes
Code Table(3-b) [a]Function 0x0D 0x0E [b]Range/Switch code Multi Position (x4)* Over Scan 0x00 Position1 0x01 Position2 0x02 Position3 0x03 Position4 0x04 Position5 0x05 Position6 0x06 Position7 0x07 Position8 0x08 Position9 0x09 Position10 0x0A Position11 0x0B Position12 0x0C Position13 0x0D Position14 0x0E Position15 0x0F Position16 0x00 OFF 0x01 ON Command Control Enquiry Standby Power On Yes Yes Disable Enable Yes Yes Disable Enable * Arrangement of M
(b) Serial Number Syntax Header Category Function Data1 Data2 Check Sum Enquiry 0x83 0x30 0x01 0xFF 0xFF 0xB2 Answer Header Answer Return to Data Size Return Data1 Return Data2 Return Data3 Return Data4 Check Sum Enquiry 0x00 0x05 Upper 8bit Data MiddleUpper Data MiddleLower Data 0x70 Lower 8bit Data 0xXX Completed Return Data1-Data4: 0x001E8480_0x002DC6BF (2,000,000-2,999,999) (c) Operation Time Syntax Header Category Function Data1 Data2 Check Sum Enquiry 0x83 0x30
(f) Shutdown Log Syntax Header Category Function Data1 Data2 Check Sum Enquiry 0x83 0x30 0x11 0xFF 0xFF 0xC2 Answer Header Answer Return to Data Size Return Data1 Check Sum Enquiry 0x70 0x00 0x02 Shutdown Log Code Table(4-c) 0xXX Completed Return Data1: 0x00–0xFF Code Table(4-c) Shutdown Information bit0 Reserved bit1 1: FAN movement abnormal 0: Normal bit2 1: Panel communication abnormal 0: Normal bit3 1: Temperature sensor abnormal 0: Normal bit4 1: Main power abnor
Code Table(4-d) [a]Function [b]Range/Switch code Command Control Enquiry Standby Power On 0x00 Model Name 0x08-0x09 No Yes Enable Enable 0x01 Serial Number 0x001E8480-0x002DC6BF Yes Yes (2,000,000_2,999,999) Enable Enable 0x02 Operation Time 0x00000000-0xD693A3FF (0sec._3,599,999,999sec.) Yes Yes Enable Enable 0x03 Soft Version (Main) 0x0000-0xFFFF No Yes Enable Enable 0x07 Digital 3.
The material contained in this manual consists of information that is the property of Sony Corporation. Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual without the express written permission of Sony Corporation. Le matériel contenu dans ce manuel consiste en informations qui sont la propriété de Sony Corporation.