Modem User Manual

Configuring the MP Modem to Report GPS and I/O
Data
Rev 1.5 Jul.08 59
Digital I/O setup
TheDigitalInput/Outputwindow(Tools > Options > MP >
Input/Output > Digital I/O)isusedtoconfiguredevicesonthetwo
digitalI/Oandtwodigitalinputports.Eachtabcorrespondsto
apin:
Toconfigureadigitalsensororgauge,selectthetabthatcorre
spondstothepinyouareusingandcompletethefieldsas
follows:
Label:Provideadescriptionofthesensororgauge,upto
20charactersinlength.
Type:SelectInput,Output,orNot used.(Outputisnot
availableontabs3and4.)
Logiclowname:Describethestateofthedeviceatlogic
levellow,upto20
charactersinlength.(Forexample,ifa
switchintheoffpositionleadstoalogiclow,youcould
choosetolabelit
Switched Off.)
Logichighname:Describethestateofthedeviceatlogic
levelhigh,upto20
charactersinlength(suchasSwitched
On
).
Alarmlogiclevel:AssignanactionassociatedwiththeI/O
port:
· high:Anotificationissent,andtheeventislogged,ifthe
statechangesfromalogiclowtoalogichigh.
· low:Anotificationissent,andtheeventislogged,ifthe
statechangesfromalogichightoalogiclow.
· logonly:Nonotificationissent,butanychangeinlogic
levelislogged.
Thenameandlocationofthelogfileisspecifiedinthe
Input/Outputwindow(
Tools > Options > MP > Input/Output).
Bydefault,thelogfileislocatedintheprogramfolderor
userfolderandiscalledMpIoLog.txt.
Currentvalue:Showsthecurrentvalueoftheport.
Digital Tab Connector Pin
I/O 1 Input or output on pin 3
I/O 2 Input or output on pin 11
Input 3 Input on pin 4
Input 4 Input on pin 12