SONY AIT-3Ex drive SDX-800V series Ver.1.1
3-3
3.1.3. Parity Disable Jumper
Parity check function can be disabled by Jumper. Parity check is disabled while left end jumper is installed. Parity
generate function is always enabled.
Parity Setting
Disable |
Enable :
: = OPEN Jumper not installed
| = CLOSED Jumper installed
3.1.4. Data Compression ON Switch
Data compression can be selected by DIP switch.
Table 3-3: Data Compression Switches
DC Control-1 DC Control-2 Definition
OFF OFF Compression disabled at power-on. The host is allowed to control
compression.
OFF ON Compression disabled at power-on. The host is not allowed to control
compression.
ON OFF Compression enabled at power-on. The host is allowed to control
compression.
ON ON Compression enabled at power-on. The host is not allowed to control
compression.
3.1.5. Power Connector
The power connector is illustrated as Figure 3-4.
5V GND GND 12V
4 3 2 1
Figure 3-4: Power Connector
3.1.6. SCSI 68 pin Connector
Figure 3-5 illustrates SCSI 68 pin connector, and table 3-4 shows the assignments for the pins of the connector.
Pin 34 1
Pin 68 35
Figure 3-5: Non-shielded SCSI Device Connector
SDX-800V supports both Low-Voltage-Differential SCSI configuration as shown table 3-4 and Single-Ended SCSI
configuration as shown table 3-5. SDX-800V detects and switches SCSI configuration between
Low-Voltage-Differential and single-ended modes by monitoring DIFFSENS signal assigned pin 16 in SCSI bus.
(Refer to table 3-4)