User Guide
Table Of Contents
- Table of Contents
- Overview
- Operating the Camera
- Administrator and User
- Logging in to System
- Configuration of Main Viewer
- Main menu
- Control panel section
- Monitor image
- Plug-in free viewer
- Using Solid PTZ function
- Controlling via the control panel (Operation common to Area zoom mode and Vector dragging mode)
- Panning and tilting by clicking the monitor image (Area zoom mode only)
- Panning, tilting and zooming by specifying the area (Area zoom mode only)
- Panning and tilting by dragging the screen (Vector dragging mode only)
- Switching Transmission Mode
- Administrating the Camera
- Basic Operations of the Administrator Menu
- Configuring the System - System Menu
- Setting the Camera Image and Audio - Video / Audio Menu
- Configuring the Network - Network Menu
- Setting the Security - Security Menu
- Setting the PTZ control - PTZ control Menu
- Setting the Sensor input/Camera tampering detection/Motion detection - Action input Menu
- Event condition Tab
- Sensor input Tab - Set the sensor input 1/2
- Camera tampering detection Tab - Set the camera tampering detection
- Motion detection Tab - Set the motion/VMF detection
- What is VMF
- Setting items for motion detection
- VMF settings
- Network disconnection Tab - Monitoring the connection of a specified IP address
- Setting the Action output - Action output Menu
- Setting the Schedule - Schedule Menu
- Others
Administrating the Camera
Setting the Sensor input/Camera tampering detection/Motion detection — Action input Menu
31
Trigger speed
Specify the minimum and maximum speeds to be
detected.
• Min. speed and Max. speed can be specified within a
scale of 100.
• The blue marker for minimum speed cannot be set to
the right of the red marker for maximum speed.
• The squares indicating Min. speed and Max. speed
move on the right and left sides of the preview screen.
Note
The set value is only valid under the conditions of
Intrusion or Passing.
Matching decision
Select the filter type you want to match and check Use
as matching condition.
Select Filter 1, Filter 2 and Filter 3 in the list box of
Matching decision.
Set the alarm to sound when the specified maximum 3
conditions occur in sequence. If the conditions occur in
a different order, the alarm will not sound. Select the
condition from Intrusion, Passing or None.
Filter order switching button
Clicking switches the order of filter between the
neighouring methods.
e.g., If you click the button between 1 and 2, they will
switch order. If you click the button between 2 and 3,
they will switch order.
Specifying the time
Specify the reference interval in seconds between 1 and
2, or 2 and 3.
For example, if 1 and 2 are set and “3 seconds” is
specified, an alarm will sound when the inspection
conditions of 2 are met within 3 seconds from when the
inspection conditions of 1 are met.
x
VMF status indicator
The indicator is on when the set filter type conditions are
met.
Full-screen display button
Click to display the ActiveX area in full screen.
Clicking again will show the normal display.
Stretch bar
Click to hide the menu list on the left and enlarge the
preview screen.
Clicking again will show the menu list as it was before.
OK/Cancel
Click OK to finalize any changes made to the settings
and send them to the camera.
If you click Cancel, changes made to the settings will be
discarded and the screen will be reloaded with the
current camera settings.
Network disconnection Tab
— Monitoring the connection of a
specified IP address
IP address monitoring
Set the specific IP address of which the network
connection status is to be monitored.
IP address monitoring is not available for IPv6.
OK/Cancel
See “Buttons common to every menu” on page 14.