User Manual

SYSTEM Setup Menu
46
Chapter 5 Menu Details
SYSTEM Setup Menu
Setting Item Settings
FILE LIST FILE LIST Displays a list of recording files and allows recording files
to be selected and file operations to be performed.
For details, see “FILE LIST Operations” (page 38).
SORT Sorts the files in the FILE LIST screen.
DATE: Date order
NAME: Name order
DURATION: Order of file recording length
SIGNAL FORMAT
Settings of signal
formats
RESOLUTION Sets the effective pixel count and scanning method.
1920 × 1080I [1920 × 1080I]
1920 × 1080P [1920 × 1080PsF/P]
FRAME Sets the operation frame frequency.
23.98 [23.98]: Frame frequency of 23.976 Hz
24 [24]: Frame frequency of 24 Hz
25 [25]: Frame frequency of 25 Hz (field frequency of
50 Hz)
29.97 [29.97]: Frame frequency of 29.97 Hz (field
frequency of 59.94 Hz )
50 [50]: Frame frequency of 50 Hz
59.94 [59.94]: Frame frequency of 59.94 Hz
SIGNAL Sets the sampling format.
422 [4:2:2]: 4:2:2 (Y/Cb/Cr)
444 [4:4:4]: 4:4:4 (R/G/B)
ENCODE Sets the video recording format and recording rate.
SR-SQ, SR-Lite
For details, see “About Recording/Playback Formats
(page 58).
TEST SG
Settings of test signal
output
Note
The VIDEO and
AUDIO settings are
both reset to “OFF”
(factory default
setting) when the
power is turned off.
VIDEO Selects the test signal to generate with the internal video
signal generator.
OFF [Off]: Does not generate a test signal.
CB [Color Bar]: Color bar signal
SMPTE [SMPTE Color Bar]: SMPTE color bar signal
RP219 [RP-219 Color Bar]: RP-219 color bar signal
BLK [Black]: Black signal
AUDIO Selects the test signal to generate with the internal audio
signal generator.
OFF [Off]: Does not generate a test signal.
1KHz [1KHz Sine]: 1 kHz sine wave
NONE [Silence]: No sound