User's Manual

5
E RF level meter
Indicates the RF input level. The number of segments that
light up depends on the input level.
6 segments lit: 60 dBµ or higher
5 segments lit: 50 to 60 dBµ
4 segments lit: 40 to 50 dBµ
3 segments lit: 30 to 40 dBµ
2 segments lit: 20 to 30 dBµ
1 segment lit: 10 to 20 dBµ
All segments off: 10 dBµ or less
F Battery level indicator
Displays the battery level. “EXT” is displayed when
power is supplied from the USB connector. “MI” is
displayed when power is supplied from an SMAD-P3D
(not supplied).
For details, see “Battery level indicator” (page 6).
h SET button
Changes the item to be set or enters the selected function
or parameter value.
i MENU button
Switches the menu that appears in the display.
j PHONES (monitor) connector (3.5-mm diameter,
stereo mini jack)
Connect to headphones to monitor the audio output.
Do not connect headphones with a monaural mini jack.
This may short-circuit the headphone outputs, resulting in
distorted sound output.
k OUTPUT 1/2 (audio output 1/2) connectors
(3.5-mm diameter, stereo mini jack, balanced
output)
Connect one end of the supplied XLR-BMP conversion
output cable or the stereo mini plug-BMP conversion
cable here and the other end to the microphone input on a
camcorder, mixer, or amplifier. If the microphone input
connector on the connected device is a stereo mini jack,
connect the straight (BMP) plug to the tuner and the L-
shaped (stereo mini) plug to the microphone input
connector on the device.
To prevent damaging the tuner, do not apply a voltage to
this connector from a microphone external power supply
or other source.
l MIC INPUT (audio input) connector (3.5-mm
diameter, stereo mini plug)
Connect to a plug-in power external microphone or Sony
BMP-type lavalier microphone.
m POWER switches
Turn tuner 1 and tuner 2 on or off individually.
n USB connector (Micro B type)
Connect to a commercially available USB portable power
supply.
When the power is turned on, the unit operates with
power supplied by the USB portable power supply. When
nickel metal hydride batteries are inserted and the power
is turned off, the battery is charged by the USB portable
power supply.
Alkaline batteries and lithium batteries cannot be
recharged.
o Auxiliary connector
Used to connect external accessories.