User guide
2/8
Form 316 (01.13) ©SOR Inc. 
Process Connection
Dimensions are for reference only.
Contact the factory 
for certified drawings 
for a particular model number.
Linear = mm/inches
Drawing 0091417
Securely connect the process line to the pressure connection using two wrenches; one to hold 
the wrench flats on the pressure port, the other to tighten the process pipe or tube fitting.
Ensure that the process connection is tightened and positioned so 
that bending and torsional forces imposed on the pressure switch are 
minimal. Do not loosen the pressure port from the body or the body from 
the housing, because leakage could result or the pressure switch could 
be rendered inoperative.
One vent connection should be  tted with a suitable breather to maintain 
weathertight rating NEMA 4, 4X, IP65 or vented to a safe area. Piping 
should be minimum 1/4” diameter and maximum 5 meters long (based 
on process  uid SG 1.0). The other vent connection may be plugged.
Safety Integrity Level (SIL) Installation Requirements
The SOR pressure switches have been evaluated as Type-A safety related hardware. 
To meet the necessary installation requirements for the SIL system, the following 
information must be utilized:
  Proof Test Interval shall be one year.
  Units may only be installed for use in Low Demand Mode.
  Products have a HFT (Hardware Fault Tolerance) of 0, and were evaluated in a 
  1oo1 (one out of one) configuration.