Instructions / Assembly

Command®3ME Poast Plus®
Conclude® Princep 4L®
Conclude®xtra Prowl®
Contour Detail™
Diesel Fuel Oil.Adend®
Doubleplay® Dual®
Dual II® Eptam 7E®
Ethylene Glycol Fallowmaster®
Flexstar® Frontier®
Fultime® Furadan®
Fusion® Gramoxone Extra®
Gramoxone lnteon™ Prowl®
3.38EC Pursuit® Reex®
Rezult® Ridomil Gold®
Roundup® Sodium Hydroxide(50%)
Squadron® Storm®
Surpass® 100 Surpass® EC
Superboll® Topnotch®
Touchdown® Trean™
Trean™ HFP Water
** Requires optional EPDM Seals
Aatrex®, Aatrex® 4L., Bicep®, Bicep 11®, Dual®, and Dual 11® are registered trademarks
of Syngenta Corporation. Broadstrike and Trean are registered trademarks of Dow
AgroSciences. Banvef®, BanvelSGF®, Blazer®, camix, Clarity®, Conclude®, Galaxy®,
Guardsman®, Lumax, Manifest “Marksman® Poast®, Poast HC®, Poast Plus®. Rezult®,
and Storm® are registered trademarks of BASF. DoublePlay®, Eptam® 7E, FulTime, Fu-
sion®, Gramaxone® Extra, Karate®, ReHex®, Surpass®. TopNotch, and Touchdown® are
registered trademarks of Syngenta. Contour®.Detail, Pursuit®, Prowl®, and Squadron®
are registered trademarks of American Cyanimld.Harness® Xtra, Roundup® are registered
trademarks of Monsanto Company. Command®, and Furadan® are registered trademarks
of FMC.Agrotain® Isa registered trademark of IMCAgrico. Superboll®is a registered
trademark of Grifn.
The 820, 825, & 850 Digital Meters are NOT
compatible with very strong acids or if uid ash point
is below 100°F(38°C). If in doubt about compatibility
of a specic uid, contact supplier of uid to check
for any adverse reactions to the listed materials of
construction (page 2).
Not for use with uids that have a ash point
below 100°F (37.8°C, ie: gaso line, alcohol).
Refer to NFPA 325M (Fire Hazard Properties of
Flammable Liquids, Gases, and Vola tile Solids)
for ash points of common liquids. Static electric-
ity buildup and discharge could result in arc and
explosion!
Options
EPDM Seals
Installation
Use Teon tape or thread compound on all threaded
joints.
1. Determine direction for uid ow and point arrow
on meter body in that direction.
2. Thread hose or pipe into ports until snug. Be careful not to
cross thread when starting threads.
Installation Hint
To prevent cross threading, turn the pipe / hose backwards
(counterclockwise) until you feel it engage threads, then
tighten.
Changing Meter Readout Position
If it is necessary to change position of the meter readout,
follow these steps (Refer to exploded view) .
1. Unscrew meter cap (item 1). Use a strap type oil lter
wrench if too tight to unscrew by hand.
2. Insert a wide, at-head screwdriver into the upper slot and
gently pry up electronics module (see Figure 1).
3. Gently rotate electronics module to desired location.
5. Press electronics module down into meter cover in the
correct orientation.
6. Thread on meter cap until hand tight. To check tightness,
there should be approximately 1/16” gap between the cap
and ridge on outlet port (see gure 3).
1/16" GAP
3