users manual

888 User Guide
28
System
TONE SETUP Selects the level, frequency, and routing of the internal
tone generator.
a. Level- Selects the level of the tone generator from -20 - 0 dBFS in 1
dB increments. [-20 - 0 dBFS]
b. Frequency- Selects the frequency of the tone from 100 to 10 kHz in
10 Hz steps. [100-10 kHz]
c. Track- [1-16]
d. Output- [L,R, X1-X6]
e. Bus- [L,R, 1-8] (Use toggle Switch Action menu to select tone as
Continuous or L-ident.)
NOTIFICATION BELLS Selects settings for the notication bells.
a. To HP- Routes notication bell tones to the headphones. [HP-L,
HP-R]
b. To Bus- Routes notication bell tones to the buses. [L,R, 1-8]
c. When…- Selects when the notication bell tones are used. [Rec/
Stop, Space Low, Power Low, Warning Popup]
d. Level- Selects the level at which the notication bell tones will be
played in 1 dB increments. [Muted, -60 to -12 dBFS]
FADER CALIBRATION Selects the option to manually calibrate all
faders.
TIMECODE CALIBRATION Tunes the 888 system clock to an
external LTC signal.
BRIGHTNESS
Selects the brightness of the LED display and front
panel LEDs.
a. LED Brightness- Selects the front panel LED brightness in 10%
steps. [10%-100%]
b. Selects the front panel LCD display brightness in 10% steps. [10%-
100%]
TIME/DATE Selects the current date and time.
a. Time Format- [12*, 24 hr]
b. Date Format- [mm/dd/yy*, dd/mm/yy, yy/mm/dd]
c. Set Time/Date- Selects the current date and time.
d. Time Zone- [-12 to +13 hours GMT]
e. Daylight Saving- [On, Off*]
TOGGLE SWITCH ACTION
Chooses what function is assigned to
the toggle switches.
MENU + PFL SWITCH ACTION Chooses what menu is assigned to
a Menu + PFL Switch action.
VERSION INFO Indicates current rmware version.
REGULATORY Displays relevant compliance information.
FIRMWARE UPDATE Selects any PRG update les present on any
media.