User Manual

970 User Guide and Technical Information
v. 2.00 Features and specifications are subject to change. Visit www.sounddevices.com for the latest documentation.
50
Setup Menu Options
# Parameter Name Description Options
4
Auto-Record Hold Off
Sets the duration that a valid timecode signal has to
be recognized by the 970 before generating a new
take when using external timecode to trigger record-
ing (When [Remote Control - Rec Start/Stop]
is set to Timecode).
» 0 sec
(numeric 0-8)
5
Jam Received TC
Opens a dialog that displays incoming timecode
value in realtime (RxTC), incoming userbits (UB),
transmitting/internal (Ambient® Lockit) timecode value
(GENTC), and transmitting/internal userbits (UB).
Push Control Knob to jam inter-
nal timecode to incoming (RxTC)
timecode.
Push MENU Button to back out.
6
Jam time Of Day
Sets the internal timecode clock to the current time
of day.
7
Set Generator TC
Sets the Ambient® Lockit timecode generator value in
HH:MM:SS.Fast Forward format.
» 00:00:00.00
(Timecode value)
8
Set Generator UBits
Sets userbits of the Ambient® Lockit timecode
generator.
» 00 00 00 00
(Hex: 00-Fast Forward for each
slot)
9
File Start TC Offset
Sets the offset of the beginning timecode stamp of
recorded files. Useful when there is a constant offset
between camera and 970 recorded files. The applied
offset does not affect timecode output of the 970.
» 0
(numeric -10 to +10)
Remote Control
# Parameter Name Description Options
1
RS422
Enable or disable RS422 capability
• On
» Off
2
Rec Start/Stop
Enable or disable automatic recording with the pres-
ence of running timecode at the timecode input.
» Off
• Timecode
3
GPIO Inputs
Set GPIO inputs (pins 1, 2, and 3 on GPIO connector)
to active high or active low. Active high: Connecting
the pin to +5V will activate the function. Active low:
Connecting the pin to ground will activate the function.
» Active low
Active high
4
GPIO Outputs
Set GPIO outputs (pins 6, 7, and 8 on GPIO connec-
tor) to active high or active low. Active high: When the
function is true, +5V will appear on the pin. Active low:
When the function is true, the pin will be grounded.
Active low
» Active high
Network
# Parameter Name Description Options
1
This 970’s Name
Sets name of 970. This must be unique within a
network.
» 970
2
Network Group
Groups the 970 with PIX 250i, PIX 260i, PIX 270i, and
970 units on the network.
» No Group
Group 1
Group 2
Group 3
Group 4
3
Dante Redundancy Mode
When On the 970’s Primary and Secondary Ethernet
ports both transmit Dante Audio over separate net-
works. This provides a fail safe of the Dante system if
one of the networks should fail. In Dante Redun-
dancy Mode, two separate networks must
be run and they CANNOT be connected to
one another. Connect any computer running
Dante Controller to the 970’s PRI Ethernet
network.
» Off
• On