Owner's Manual

RKDT/PPLX WIRING CONNECTIONS
WIRE COLOR REMOTE OPEN STANDALONE LED CONTROL WIEGAND
GREEN DATA-0 DATA-0
WHITE DATA-1 DATA-1
VIOLET RXD N/A
GRAY TXD N/A
ORANGE GREEN LED INPUT (3, 1) GREEN LED INPUT (3, 1)
BROWN REX LATCH + TIMER (2, 1) RED LED INPUT (3, 1)
YELLOW BEEPER INPUT (1) BEEPER INPUT (1)
BLUE HOLD (1) HOLD (1)
RED 5-14 VDC + 5-14 VDC +
BLACK GROUND --- GROUND ---
WHITE/BLACK RELAY + NA
WHITE/BROWN RELAY - NA
(1) Connect to GROUND to activate
(2) Input Programmed for Remote Open
(3) Input Programmed for LED/Beeper Control
SPECIFICATIONS:
POWER REQUIREMENTS
5-14 VDC, 150 mA Max.
OUTPUTS
SPST Solid State Relay, 1A max. @60 VAC or DC
Normally open or normally closed (eld programmable) (See Operating Guide).
INPUTS
Default is Remote Open (requires contact closure).
Also programmable as Red LED Control for online systems (see Operating Guide).
Additional inputs for Green LED, Beeper and HOLD are available in Wiegand mode.
WIEGAND OUTPUT
Any Wiegand Format up to 40 bits
Maximum Distance: 500 ft. - 5 or 8 conductor 20 gauge cable
ENVIRONMENT
Access Control Unit, Key Tags and Cards
Ambient Temperature -40° to +70°C (-40° to +158°F)
Humidity 0 to 95% (non-condensing)
PARTS SUPPLIED:
Access Control Unit
MOV
Operating Guide
Installation Instructions
Log Sheet
RKDT-SA-S/RKDT-WM/PPLX RKDT-SA-M
Mounting Plate 2, #6 Mounting Screws
2, #6 Mounting Screws Cable Assembly
1, 4x40 Screw Decorative Cover
1, Security Screw
1, Cable Assembly
1, Snap-In Labels (RKDT-WM Only)
ACCESSORIES (NOT INCLUDED):
RK-HHP Hand-Held Programmer
RK-PS: 9VDC Plug-in Power Supply. It is designed to power
the RKDT-SA-M/SA-S.
Requires 110 Volts AC power.
SK-SR SecuRelay™ - Smart Relay Module DPDT.
3322252 7472
20301 Nordhoff Street, Chatsworth, CA 91311
PHONE (818) 882-0020 • FAX (818) 882-7052
TOLL-FREE (800) 891-0020
Website: www.securakey.com • E-mail: mail@securakey.com
INSTRUCTION TO THE USER
FCC ID: NNHDTR1
This equipment has been tested and found to comply with the limits for a class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency
energy and if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more or the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet of a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
In order to maintain compliance with FCC regulations, unshielded cables must be used with this equipment. Operation with non-approved equipment or
shielded cables is likely to result in interference to radio and TV reception. The user is cautioned that changes and modications made to the equipment
without the approval of manufacturer could void the user’s authority to operate this equipment. “This device complies with Part 15 of the FCC rules. Operation
is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
OUTPUT RELAY
REMOTE OPEN
TYPICAL INSTALLATION
LOCK
POWER
SUPPLY
12
VDC
+
MAGLOCK
*/
STRIKE
NORMALLY OPEN
SWITCH
WHITE/BROWN
BROWN
BLACK
WHITE/BLACK
RED
BLACK
VOM
µ
POWER
SUPPLY
READER
* Relay defaults to Normally Open.
For Maglock, see “Configure Relay Output” section in Manual.
Note: Use separate power supplies for maglock / strike
and for access control unit.
MAGLOCK /
STRIKE
ACCESS
CONTROL
UNIT
LOCK
POWER
SUPPLY
DC
+
_
RELAY +
RELAY -
INSTALL
MOV HERE
Installation of Metal Oxide Varistor
Install the enclosed 40-volt MOV (Metal Oxide Varistor) across
the relay contacts in the access control unit, as shown. The
Access Control Unit must have its own power supply.
RoHS