User's Manual

Radio Key
®
RK-65K Operating Guide
Secura Key 18
Using the RK-65K as a Wiegand Output Reader
(RK65K/RK100M)
The RK-65K can be connected to a multidoor access control
system (such as the Secura Key SK-ACP) using the Wiegand
output. When any Radio Key
®
transponder is presented to the
unit, whether or not it has been programmed into the unit, the
appropriate transponder ID will be sent out via the white and
green wires.
Program the Input (RK65K/RK100M)
The input is set at the factory as a Remote Open input.
Connecting the brown and the orange wire (usually with a push
button switch) will activate the relay for the time set for the latch
timer. This input may also be confi gured as an LED control or
as an LED/beeper control. When confi gured as an LED control,
grounding the brown wire will turn on the Red LED, grounding
the orange wire will turn on the Green LED and grounding the
yellow wire will turn on the beeper.
To confi gure the input, put the unit into the Program mode,
(See Page 8). Press THRU TWICE. Then press either the “1”
or “2” button. Press ENTER. Selections are:
“1” - Remote Open (Factory default).
“2” - LED Control.