LOCAL IO
Figure 14-13: System - Local I/O Page
This page displays a graphical representation, and the current status, of the cards in the Local Rack. It also
shows the status of the PSU(s)and the status of the voltages for the analogue (VA) and digital (VD) power
supply rails. The cooling fan status is also reported. A blue label under the card indicates that it equipped
with inputs, a red label indicates that it is equiped with outputs. Some cards have both inputs and out-
puts, they are shown with both colours in triangles.
If the card conguration of the Local Rack is changed (e.g., when optional cards are tted in place of ex-
isting cards), the card labels will be automatically updated with the new card types if the ‘Recong’ button
on the Local Rack has been pressed after changing the cards.
If an optional card has been tted and the word ‘BLOCKED’ is shown in place of ‘OK’, this means that the
new card has exceeded the total number of allowed input and output channels within the system (192
inputs and 192 outputs). This can happen particularly if additional MADI cards are tted. In this case it is
necessary to limit the number of channels on the new cards by changing their DIP switch settings.