Operation Manual
Soundcraft Vi Series™ User Guide 1112 Page 14 - 17
STAGE BOX
Figure 14-14: System - Stage Box Page
This page displays a graphical representation, and the current status, of the cards in the Stage Box. It also
shows the status of the PSU(s) and the status of the voltages for the analogue (VA) and digital (VD) power
supply rails. The cooling fan status is also reported.
A blue label under a card display indicates an input function, and a red label indicates an output function.
If the card conguration of the Stagebox is changed (e.g., when AES input or output cards are tted in
place of the analogue cards), the card labels will be automatically updated with the new card types if the
‘Recong’ button on the Stagebox front panel has been pressed after changing the cards.
The <R01> to <R06> buttons at the top of the screen are illuminated to show the connected Stage
Box(es). These buttons relate to the valid double slots in the Local Rack where a MADI card could be con-
nected. The default position when only one Stage Box is connected is R05.