Operation Manual

Soundcraft Vi Series™ User Guide 1112Page 15 - 16
CUE LIST PAGE - Cue Number Field Touched
Figure 15-11: Cue Number Field Touched.
Touching the Cue Number area of the highlighted Cue switches the Vistonics encoders below to a new
mode that allows specic parameters relating to this Cue to be edited.
CUE ENABLE {ON} key: Enables/disables the recall of this Cue in the List. When set to OFF, the Cue is
jumped over in the list, if the [NEXT] and [LAST] keys are used to sequentially recall Cues. The Cue can still
be selected by the scroll or up/dwn arrow keys on the surface (to allow editing of properties) but cannot
be recalled by pressing the [RECALL] key (ie: no desk snapshot recalled, no events generated).
When set to off, the whole Cue appears greyed out in the Cue List.
SEQUENCER
The sequencer functionality allows auto-triggering of another Cue at a preset time delay after this Cue has
been recalled. In this way several Cues can be ‘chained’ together.
GO TO CUE {ON} key: Enables/disables the sequencer function.
GO TO CUE encoder: Selects the Cue number of the Cue that will be triggered after the set time interval.
(The numbers in the eld match the current Cue List numbers).
AFTER SEC: encoder: Sets the time delay after which the Cue specied in the GO TO eld is recalled.
Range 0- 30s, in 0.5s steps.
TIMECODE encoders: Allows a MIDI timecode value to be set (Hrs:Mins:Secs:Frames). The Cue will be
recalled automatically when the set timecode value is received at the MIDI In, if the ON button is enabled.
There is also a global Timecode ON switch in the Menu \MIDI page which must be enabled in order for
timecode triggering to occur. Timecode frame rate is detected automatically, and the value of the received
timecode is displayed in the INCOMING eld..
The {COPY} key transfers the value in the INCOMING eld to the encoders.
The {STEAL} key becomes active if the whole Timecode value matches one that is already assigned to
another Cue. Pressing {STEAL} will reassign this value to the current Cue. The default value of all elds will
be ‘-‘ (= no value). The values will be shown greyed out if they match the values of another cue.