Operation Manual

Soundcraft Vi Series™ User GuidePage 23 - 22
SCore Live
3-12 Modules Date printed: 03.04.08
LED: EXT LOCK Indicates that the applied external sync is used by the system.
DIP Switch:
S2 Setting
1.1
VIDEO IN termination (default setting OFF: High-Z / ON: 75 )
1.2
reserved (default setting OFF)
1.3
reserved (default setting OFF)
1.4
WCLK IN termination (default setting OFF: High-Z / ON: 75 )
Connector Pin Assignment: AES SYNC IN + 3x OUT (15-pin D-type, female)
Pin Signal Pin Signal
1
AES IN +
9
AES IN –
2
Screen
10
Screen
3
AES OUT 3 –
11
AES OUT 3 +
4
n.c.
12
n.c.
5
AES OUT 2 +
13
AES OUT 2 –
6
Screen
14
Screen
7
AES OUT 1 –
15
AES OUT 1 +
8
n.c.
1.1
1.2
1.3
1.4
S1
OFF
1
8
15
9
Solder/Crimp View