Operation Manual

Soundcraft Vi Series™ User Guide 1112 Page 4 - 15
COMPRESSOR Function
THRS Field
Encoder adjusts the threshold value between -40 db to +18dB.
{IN} enables the COMPRESSOR.
ATCK Field
Encoder adjusts the attack time in the range 0.5mS to 98.6mS.
REL eld
Encoder adjusts the release time in the range 5.5mS to 5S.
Ratio eld
Encoder adjusts the ratio in the range 1:1 to 20:1.
MKUP
Makeup adjusts the overall output level from the Limiter and Compressor sections.
GAIN
Encoder manually adjusts the output level to compensate for gain reduction.
{AUTO} automatically adjusts the output level depending on the settingd of the THRS and RATIO controls.
LIMITER Function
THRS Field
Encoder adjusts the threshold value between -40 db to +18dB.
{IN} enables the LIMITER.
ATCK Field
Encoder adjusts the attack time in the range 10µS to 98.6mS.
REL Field
Encoder adjusts the release time in the range 5.5mS to 957mS.